• About us
    • BIBUS Portugal, Lda
    • Contact
    • News
    • Our suppliers
    • Downloads
    • Technology group
    • BIBUS HOLDING
    • Locations
    • Strategy
  • Mechanics
    • Industrial gas springs
    • Electrical Linear Actuators
    • Damping, Tensioning, Suspension and Anti-Vibration
    • Linear bushings and screws
    • Motorized lead screws
    • True planetary gearheads
    • Worm gear screw jacks
    • Clutches & brakes
    • Electric units for drilling and tapping
    • Servo technology
    • Transmission technology
    • Switch & sensor technology
    • Safety handling of reels
    • Presses
    • Mechanical & rubber parts
  • Electrical
    • Safety and industrial control equip.
    • Sensors and vision
    • Step technology
    • Electrical Linear Actuators
    • IoT and AI Solutions for Industrial Safety & Efficiency
    • Inductive, capacitive and touch sensors
    • Pick by light
    • Electric wheel
    • Pressure Transducer
    • Digital USB Pressure Transducer
    • Digital USB Pressure Transducer (ESI)
    • Fluxostat. Special sensors
    • Safety
    • VarioShaker
    • Level and temperature measurement
    • Flow technology (MEISTER-FLOW)
  • Pneumatics
    • Deceleration technology
    • Rotating unions
    • Pneumatic coolers
    • Pneumatic automation
    • Pneumatic cylinders
    • Valves and electrovalves
    • Connectors & accessories
    • Air treatment
    • Instrumentation
    • Safety chucks
    • Expansion units
    • Vacuum technology
    • Pneumatic feeders
    • Air motors
    • Agitation systems
    • Pneumatic vibrators
    • Vibration isolation
    • Indexing table with servomotor
    • Stop and positioning modules
  • Hydraulics
    • Hydraulic motors
    • Hydraulic pumps
    • Hydraulic valves
    • Hydraulic coolers
    • Rotary hydraulic actuators
    • Hydraulic cylinders
    • Filtration technology
    • Flow measurement
    • Hydraulic accumulators
    • Automatic lubrication systems
    • Hydrostatic components
    • Pipework equip. Hydr. components
    • Pressure amplifiers
    • Gear Boxes/Brakes
    • Hydraulic aggregates (CAPRONI)
    • Hybrid systems
    • Easymotion
  • Environmental technology
    • Blower technology
    • Control and dosing systems
    • Dosing pumps
    • Fluid proccess valves
    • Diaphragm blowers
    • Diffusors
    • AODD pumps
    • Magnetic drive pumps
    • Peristaltic pumps
    • Drum pumps
    • Vertical agitators
    • Sanitary pumps and unloading systems
    • Legionella testing kits (HYDROSENSE)
    • Process valves for water
    • Water flow sensors (CKD)
    • Condensate drains. Oil water sep.
    • Controllers
    • Pressure Switches for Water
    • Mechanical Pressure Switches for Hydrogen
    • Digital USB Pressure Transducer (ESI)
  • Life Science
  • Shop
  • Português
BIBUS ... supporting your success
  • Home
  • Search

Facebook

LinkedIn

Youtube

📞@info@bibus.pt
Found 775 results in 2 milliseconds. Displaying results 651 to 660 of 775.
Results per page:
  • ....
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • ....
  1. MOOG_Radial_Piston_Pump_RKP-II.pdf
    Relevance:
     
    33%

    What moves your World RKP-II RadIal PIston PumP Moog RKP PuMPs offeR low noise, unsuRPassed Reliability, long life, and a wide vaRiety of contRol oPtions foR deManding aPPlications RADIAL PISTON PUMPS RKP–II CROSS SECTION RKP–II RADIAL PISTON PUMP RKP–II 2 1 8 5 7 9 2 3 4 6 1 Drive shaft 2 Roller bearing 3 Control piston 4 Compensator 5 Housing 6 Slipper pads 7 Sliding stroke ring 8 SAE connection 9 Drain port RADIAL PISTON PUMPS RKP–II TABLE OF CONTENTS RADIAL PISTON PUMP RKP–II 3 Contents Page Cross section 2 Table of contents 3 Introduction 4 New design 5 Technical data 6 Performance curves…

    File type: application/pdf
    Referenced at:

  2. DUPLOMATIC_Variable_Displacement_Vane_Pumps_RV1P.pdf
    Relevance:
     
    32%

    14 201/418 ED 1/12 RV1P VARIABLE DISPLACEMENT VANE PUMPS SERIES 10 OPERATING PRINCIPLE HYDRAULIC SYMBOL — RV1P are variable displacement vane pumps with hydraulic operated pressure compensator, that permit instantaneous adjustment of the flow rate according to the circuit requirements. Energy consumption is reduced and adequate in every cycle phase. — The pumping group is provided with double hydrostatic axial compensation, that improves the volumetric efficiency and reduces wear of the components. Both internal paths for inlet and outlet are double. — The pressure compensator operates keeping…

    File type: application/pdf
    Referenced at:

  3. DUPLOMATIC_Variable_Displacement_Vane_Pumps_RV1P.pdf
    Relevance:
     
    32%

    14 201/418 ED 1/12 RV1P VARIABLE DISPLACEMENT VANE PUMPS SERIES 10 OPERATING PRINCIPLE HYDRAULIC SYMBOL — RV1P are variable displacement vane pumps with hydraulic operated pressure compensator, that permit instantaneous adjustment of the flow rate according to the circuit requirements. Energy consumption is reduced and adequate in every cycle phase. — The pumping group is provided with double hydrostatic axial compensation, that improves the volumetric efficiency and reduces wear of the components. Both internal paths for inlet and outlet are double. — The pressure compensator operates keeping…

    File type: application/pdf
    Referenced at:

  4. DUPLOMATIC_Variable_Displacement_Axial-Piston_Pumps_VPPM.pdf
    Relevance:
     
    31%

    16 100/117 ED 1/32 VPPM VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS HYDRAULIC SYMBOL OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS 16 100/117 ED — The VPPM pumps are variable displacement axial-piston pumps with variable swash plate, suitable for applications with open circuits. — They are available in three different frame sizes with maximum displacements up to 29, 46, 73 and 87cm3/rev. — The pump flow rate is proportional to the rotation speed and to the angle of the swash plate, which can be continuously modulated. The maximum and minimum angle can be limited mechanically via suitable…

    File type: application/pdf
    Referenced at:

  5. DUPLOMATIC_Variable_Displacement_Axial-Piston_Pumps_VPPM.pdf
    Relevance:
     
    31%

    16 100/117 ED 1/32 VPPM VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS HYDRAULIC SYMBOL OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS 16 100/117 ED — The VPPM pumps are variable displacement axial-piston pumps with variable swash plate, suitable for applications with open circuits. — They are available in three different frame sizes with maximum displacements up to 29, 46, 73 and 87cm3/rev. — The pump flow rate is proportional to the rotation speed and to the angle of the swash plate, which can be continuously modulated. The maximum and minimum angle can be limited mechanically via suitable…

    File type: application/pdf
    Referenced at:

  6. thomson_datasheet_leadscrew_en_04-2009.pdf
    Relevance:
     
    31%

    www.thomsonlinear.com 9 LEAD SCREW S Lead Screws, Ball Screws and Ball Splines Lead Screws Table of Contents Description Page Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Advanced Anti-Backlash Supernuts . . . . . . . . . . . . . . . . 12 Flange Mount Supernuts . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Thread Mount Supernuts . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Thread Mount Bronze Nuts . . . . . . . . . . . . . . . . . . . . . . . . 29 Standard Mounting Flanges . . . . . . . . . . . . . . . . . . . . . . . . 31 Stainless…

    File type: application/pdf
    Referenced at:

  7. KRACHT_Pressure_Relief_Valves_SPV-SPVF.pdf
    Relevance:
     
    31%

    Pressure Relief Valves SPV, SPVF direct operated 2 Pressure Relief Valves SPV, SPVF direct operated Construction 1 Housing 2 Sliding piston 3 Compression spring 4 Set screw 5 Bleeding screw 6 Protective cap Description The pressure relief valve SPV/SPVF is a direct spring sli- ding piston valve. It is intended for mounting in pipe- lines and is suitable to safeguard low pressure hydraulic circuits. The pipe connection is to be effected either by SAE-mounting surfaces (3000 psi) or by Whitworth pipe threads ”G“. Notes - When using strongly aerated media, the valve should preferably be mounted…

    File type: application/pdf
    Referenced at:

  8. KRACHT_Pressure_Relief_Valves_SPV-SPVF.pdf
    Relevance:
     
    31%

    Pressure Relief Valves SPV, SPVF direct operated 2 Pressure Relief Valves SPV, SPVF direct operated Construction 1 Housing 2 Sliding piston 3 Compression spring 4 Set screw 5 Bleeding screw 6 Protective cap Description The pressure relief valve SPV/SPVF is a direct spring sli- ding piston valve. It is intended for mounting in pipe- lines and is suitable to safeguard low pressure hydraulic circuits. The pipe connection is to be effected either by SAE-mounting surfaces (3000 psi) or by Whitworth pipe threads ”G“. Notes - When using strongly aerated media, the valve should preferably be mounted…

    File type: application/pdf
    Referenced at:

  9. JORC_Timmer_Controlled_Drains.pdf
    Relevance:
     
    30%

    RELIABLERELIABLERELIABLE ENVIRONMENT SAFEGUARDDRAIN FLEXIBLITY COM PRESSED AIR CON D EN SATE M AN AGEM EN T AN D EN ERGY SAVIN G PROD UCTSCO M PR ES SE D A IR C ON D EN SA TE M AN AG EM EN T AN D E N ER GY S AV IN G PR OD UC TS JORC Industrial BV Pretoriastraat 28 NL-6413 NN Heerlen The Netherlands Tel: +31 (0) 45 524 24 27 Fax: +31 (0) 45 524 19 79 info@jorc.nl www.jorc.eu FLUIDRAIN EZ-1 TEC-11 TEC-44 COMBO-D-LUX HIGH PRESSURE TIMER CONTROLLED DRAINS TIMER CONTROLLED TIMER CONTROLLED INDEX Chapter Content Page 1 Introduction to compressed air condensate 3 Why install a condensate drain? 3 2…

    File type: application/pdf
    Referenced at:

  10. JORC_Timer_Controlled_Drains.pdf
    Relevance:
     
    30%

    RELIABLERELIABLERELIABLE ENVIRONMENT SAFEGUARDDRAIN FLEXIBLITY COM PRESSED AIR CON D EN SATE M AN AGEM EN T AN D EN ERGY SAVIN G PROD UCTSCO M PR ES SE D A IR C ON D EN SA TE M AN AG EM EN T AN D E N ER GY S AV IN G PR OD UC TS JORC Industrial BV Pretoriastraat 28 NL-6413 NN Heerlen The Netherlands Tel: +31 (0) 45 524 24 27 Fax: +31 (0) 45 524 19 79 info@jorc.nl www.jorc.eu FLUIDRAIN EZ-1 TEC-11 TEC-44 COMBO-D-LUX HIGH PRESSURE TIMER CONTROLLED DRAINS TIMER CONTROLLED TIMER CONTROLLED INDEX Chapter Content Page 1 Introduction to compressed air condensate 3 Why install a condensate drain? 3 2…

    File type: application/pdf
    Referenced at:

  • ....
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • ....

BIBUS Portugal, Lda

Centro Empresarial AAA
Rua Ponte da Pedra, 240 - C4
4470-108 Maia
Porto - Portugal

Opening hours: monday to friday 
9:00-12:30 / 14:00-18:00 

Tel. +351 22 906 50 50
Tlm +351 96 501 00 41

E-mail: info@bibus.pt

  • About us
  • Mechanics
  • Electrical
  • Pneumatics
  • Hydraulics
  • Environmental technology
  • Life Science
  • Shop
  • Imprint
  • Disclaimer
  • Privacy Practices
  • Complaints
  • www.bibus-technology.com
  • © BIBUS AG 2021 all rights reserved
Cookie Settings

We use cookies on our website. Some of them are technically necessary, while others help us to improve this website or provide additional functionality.

Show details Hide details
Necessary cookies

Necessary cookies enable basic functions and are necessary for the proper functioning of the website.

Name: resolution
Provider: BIBUS AG
Purpose: Saves screen resolution to optimise images
Cookie duration: Session duration (only as long as you are on the site)
Name: cookie_consent
Provider: BIBUS AG
Purpose: Saves which cookies are allowed
Cookie duration: 1 year
Name: cookieconsent_status
Provider: BIBUS AG
Purpose: Saves whether cookies are allowed or rejected
Cookie duration: 1 year
Statistics

Statistics Cookies collect information anonymously. This information helps us to understand how our visitors use our website.

Name: _ga
Provider: Google LLC
Purpose: Behavioural analysis
Cookie duration: 2 years
Name: _pk_ref
Provider: BIBUS AG
Purpose: Behavioural analysis
Cookie duration: 6 months
Name: _ga
Provider: Google LLC
Purpose: Analysis of clicks on PDFs and contact links
Cookie duration: 2 years
Name: _gid
Provider: Google LLC
Purpose: Identification of returning users
Cookie duration: 24 hours
Imprint | Datapolicy