Industrial Products Pumps Sizes 63, 112, 180, 280, 180DT & 280DT Up to 510 kW and 350bar @1500 rpm Swash-plate Axial Piston Pump Series K3VG Data Sheet P-1001/06.99 GB Features ◊ Reliable, High Pressure, Long Life Modular Design. ◊ Low Noise and High Efficiency. ◊ Self-Compensating piston return mechanism. ◊ Extensive Range of Highly Responsive Control Options. ◊ Auxiliary Gear Pump Option. ◊ Rated Pressure 350 Bar. ◊ Peak Pressure 400 Bar. ◊ High Continuous Power Rating. ◊ Fully Balanced Spherical Valve Plate. ◊ Infinite displacement control. ◊ Hydrostatically Balanced Swash Plate Support. ◊…
File type: application/pdf
Referenced at:
890 Series variation Metering valve with silencer Small bore size type Resin body type High noise reduction, small bore size, resin body type SMW2-6A SMW2-8A FMS-M5 SMW-10A SMW-15A SL-M5 SLW-6A/6N SLW-8A/8N SLW-10A/10N SLW-15A/15N SLW-8A-H SLW-10A-H SLW-15A-H Model / appearance Model no. Applicable cylinder bore size (mm) Page Port size (R) Effective sectional area (mm2) M3 M5 1/8 1/4 3/8 1/2 3/4 1 11/4 11/2 2 6 8 5.6 9.9 4 25 39 5 10 20 30 75 15 30 50 370 660 250 1700 2600 300 650 1300 2000 4850 1000 2000 3250 20 to 50 32 to 75 6 to 15 50 to 100 50 to 100 6 to 15 20 to 80 32 to 80 50 to 100…
File type: application/pdf
Referenced at:
Mold Coupler KC H 22 Water, Oil H 1/8 1/4 3/8 Size 21 22 23 M R1/8 R 1/4 R3/8 F Rc1/8 Rc 1/4 Rc3/8 Model Type Thread Size(T) Brass 10kgf/cm2 (1000kPa) 15kgf/cm2 (1500kPa) KC Plug KH Socket Hose Stem Male Thread Female Thread H M F KCH 170p KCM 170p KCF 170p Plug Nipple Plug Male Plug Female KHH 171p KHM 171p KHF 171p Socket Nipple Socket Male Socket Female SANG-A PNEUMATIC CO.,LTD. SANG-A PNEUMATIC CO.,LTD.168 169 MOLD COUPLER M old C oupler Structural Diagram Application Feature - Used for piping of supplying cooling water on moulds. - Quick assembly by one touch system. - Uni-directional…
File type: application/pdf
Referenced at:
www.suco.de 16 www.suco.de 16 Pressure switches hex 24 Normally open or Normally closed, maximum voltage 42 V Technical data Voltage max. 42 V Current rating (resistive): max. 4 Ampere Contact rating: 100 VA Temperature stability for diaphragm / seal materials: NBR -40 °C – +100 °C EPDM -30 °C – +120 °C FKM -5 °C – +120 °C Silicone -40 °C – +120 °C HNBR -30 °C – +120 °C Switching frequency: 200 / min. Mechanical life expectancy: 106 cycles (life expectancy of diaphragm pressure switches only for pressures up to max. 50 bar) Pressure rise rate: ≤ 1 bar/ms Hysteresis: average value 5 – 30 %…
File type: application/pdf
Referenced at:
Test Couplings Test Adaptors Test Hoses and Connectors Catalogue 7 STAUFF TestCata lo gu e 7 ST AU FF T es t Please note: Unless otherwise stated, all data and figures in this product catalogue are approximate values and are only valid as references, which are not binding (also in respect to any third parties’ rights of protection) and thus do not release the customer / user from checking and testing the suitability of the products for the foreseen purposes. Therefore, data and figures can only be used in a limited sense for construction purposes. The application of the products is beyond the…
File type: application/pdf
Referenced at:
Test Couplings Test Adaptors Test Hoses and Connectors Catalogue 7 STAUFF TestCata lo gu e 7 ST AU FF T es t Please note: Unless otherwise stated, all data and figures in this product catalogue are approximate values and are only valid as references, which are not binding (also in respect to any third parties’ rights of protection) and thus do not release the customer / user from checking and testing the suitability of the products for the foreseen purposes. Therefore, data and figures can only be used in a limited sense for construction purposes. The application of the products is beyond the…
File type: application/pdf
Referenced at:
M an ua l s w itc hi ng v al ve 4GA/B M4GA/B MN4GA/B W4GA/B2 W4GB4 4TB 4SA/B0 4SA/B1 4KA/B 4F 3MA/B0 3PA/B P/M/B 4F*0E SKH 4L2-4/ LMF0 MN3S0 MN4S0 MN3E0 MN4E0 4GA/B (Master) PV5/ CMF PV5G/ CMF NP/NAP/ NVP HMV HSV PCD/ FS/FD Ending 2QV 3QV 1181 HMV/HSV Manual switching valve4 port valve Features Low sliding movement facilitates operation A swing lever (detent integrated rotary) is used for operation. Two types available based on application Miniature type (Rc1/4) Standard type (Rc1/4, 3/8, 1/2, 3/4) Overview The HMV and HSV Series manual switching value is 4 port valves incorporating a sliding…
File type: application/pdf
Referenced at:
M an ua l s w itc hi ng v al ve 4GA/B M4GA/B MN4GA/B W4GA/B2 W4GB4 4TB 4SA/B0 4SA/B1 4KA/B 4F 3MA/B0 3PA/B P/M/B 4F*0E SKH 4L2-4/ LMF0 MN3S0 MN4S0 MN3E0 MN4E0 4GA/B (Master) PV5/ CMF PV5G/ CMF NP/NAP/ NVP HMV HSV PCD/ FS/FD Ending 2QV 3QV 1181 HMV/HSV Manual switching valve4 port valve Features Low sliding movement facilitates operation A swing lever (detent integrated rotary) is used for operation. Two types available based on application Miniature type (Rc1/4) Standard type (Rc1/4, 3/8, 1/2, 3/4) Overview The HMV and HSV Series manual switching value is 4 port valves incorporating a sliding…
File type: application/pdf
Referenced at:
M an ua l s w itc hi ng v al ve 4GA/B M4GA/B MN4GA/B W4GA/B2 W4GB4 4TB 4SA/B0 4SA/B1 4KA/B 4F 3MA/B0 3PA/B P/M/B 4F*0E SKH 4L2-4/ LMF0 MN3S0 MN4S0 MN3E0 MN4E0 4GA/B (Master) PV5/ CMF PV5G/ CMF NP/NAP/ NVP HMV HSV PCD/ FS/FD Ending 2QV 3QV 1181 HMV/HSV Manual switching valve4 port valve Features Low sliding movement facilitates operation A swing lever (detent integrated rotary) is used for operation. Two types available based on application Miniature type (Rc1/4) Standard type (Rc1/4, 3/8, 1/2, 3/4) Overview The HMV and HSV Series manual switching value is 4 port valves incorporating a sliding…
File type: application/pdf
Referenced at:
1187 Q ui ck e xh au st v al ve 4GA/B M4GA/B MN4GA/B W4GA/B2 W4GB4 4TB 4SA/B0 4SA/B1 4KA/B 4F 3MA/B0 3PA/B P/M/B 4F*0E SKH 4L2-4/ LMF0 MN3S0 MN4S0 MN3E0 MN4E0 4GA/B (Master) PV5/ CMF PV5G/ CMF NP/NAP/ NVP HMV HSV PCD/ FS/FD Ending 2QV 3QV 2QV/3QV Quick exhaust valve C O N T E N T S Safety precautions 1188 Quick exhaust valve push-in joint (2QV/3QV) 1192 Refer to the safety precautions on Introduction and page 1188 before starting use. Features Straight flow path and large effective sectional area. Flame resistance resin is used as standard. (Equivalent to UL94 standards V-0) By bracket of…
File type: application/pdf
Referenced at: