HVB41 Series 426 Solenoid valve for high vacuum HVB41 Series NC (normally closed) type Port size: NPT1/4 (O ring sheet) JIS symbol NC (normally closed) type How to order C Voltage B Option HVB 8N AC100V41 5 3H A Connection Model no. 8N 8R NPT1/4 (with O ring seat) 1/4 VCR female joint (custom order) ConnectionA Symbol Descriptions 100 VAC 200 VAC 24 VDC 100 VAC (50/60Hz) 200 VAC (50/60Hz) 24 VDC VoltageC Blank 3H 3K B Blank Square terminal box + light G1/2 Square terminal box G1/2 Mounting plate OptionB Orifice 5 HVB41-8N-* HVB41-8R-* (custom order) Specifications Note 1: The durability may…
File type: application/pdf
Referenced at:
HVB41 Series 426 Solenoid valve for high vacuum HVB41 Series NC (normally closed) type Port size: NPT1/4 (O ring sheet) JIS symbol NC (normally closed) type How to order C Voltage B Option HVB 8N AC100V41 5 3H A Connection Model no. 8N 8R NPT1/4 (with O ring seat) 1/4 VCR female joint (custom order) ConnectionA Symbol Descriptions 100 VAC 200 VAC 24 VDC 100 VAC (50/60Hz) 200 VAC (50/60Hz) 24 VDC VoltageC Blank 3H 3K B Blank Square terminal box + light G1/2 Square terminal box G1/2 Mounting plate OptionB Orifice 5 HVB41-8N-* HVB41-8R-* (custom order) Specifications Note 1: The durability may…
File type: application/pdf
Referenced at:
HVB41 Series 426 Solenoid valve for high vacuum HVB41 Series NC (normally closed) type Port size: NPT1/4 (O ring sheet) JIS symbol NC (normally closed) type How to order C Voltage B Option HVB 8N AC100V41 5 3H A Connection Model no. 8N 8R NPT1/4 (with O ring seat) 1/4 VCR female joint (custom order) ConnectionA Symbol Descriptions 100 VAC 200 VAC 24 VDC 100 VAC (50/60Hz) 200 VAC (50/60Hz) 24 VDC VoltageC Blank 3H 3K B Blank Square terminal box + light G1/2 Square terminal box G1/2 Mounting plate OptionB Orifice 5 HVB41-8N-* HVB41-8R-* (custom order) Specifications Note 1: The durability may…
File type: application/pdf
Referenced at:
HVB41 Series 426 Solenoid valve for high vacuum HVB41 Series NC (normally closed) type Port size: NPT1/4 (O ring sheet) JIS symbol NC (normally closed) type How to order C Voltage B Option HVB 8N AC100V41 5 3H A Connection Model no. 8N 8R NPT1/4 (with O ring seat) 1/4 VCR female joint (custom order) ConnectionA Symbol Descriptions 100 VAC 200 VAC 24 VDC 100 VAC (50/60Hz) 200 VAC (50/60Hz) 24 VDC VoltageC Blank 3H 3K B Blank Square terminal box + light G1/2 Square terminal box G1/2 Mounting plate OptionB Orifice 5 HVB41-8N-* HVB41-8R-* (custom order) Specifications Note 1: The durability may…
File type: application/pdf
Referenced at:
GEAR MOTORS D Series Gear Motors including Fan Drive l Technical Information Orange - CMYK 88%Y 66%M Grey - CMYK 44% Black 77C 33M 55K 50C 100Y 66M 88Y 66M 88Y D SERIES GEAR MOTORS I TECHNICAL INFORMATION2 Turolla - L1022895 • September 2013 • Rev F History of revisions Date Page Changed Rev. Feb. 2009 - First edition AA Nov. 2009 25 TY shaft uses a #8 woodruf key AB Feb. 2010 last Fix Osaka address AC April 2010 various Add reversing fan drive motor BA Nov. 2010 all Turolla colors CA July 2011 all Turolla new layout, fonts update, Sauer-Danfoss replacement. D October 2011 1 Cover page change…
File type: application/pdf
Referenced at:
GEAR MOTORS D Series Gear Motors including Fan Drive l Technical Information Orange - CMYK 88%Y 66%M Grey - CMYK 44% Black 77C 33M 55K 50C 100Y 66M 88Y 66M 88Y D SERIES GEAR MOTORS I TECHNICAL INFORMATION2 Turolla - L1022895 • September 2013 • Rev F History of revisions Date Page Changed Rev. Feb. 2009 - First edition AA Nov. 2009 25 TY shaft uses a #8 woodruf key AB Feb. 2010 last Fix Osaka address AC April 2010 various Add reversing fan drive motor BA Nov. 2010 all Turolla colors CA July 2011 all Turolla new layout, fonts update, Sauer-Danfoss replacement. D October 2011 1 Cover page change…
File type: application/pdf
Referenced at:
Gear Pumps BT, BTH Transfer Gear Pumps BT, BTH Construction KRACHT GmbH · Gewerbestr. 20 · 58791 Werdohl, Germany · fon +49(0)23 92/935-0 · fax +49(0)23 92/935 209 · mail info@kracht.eu · web www.kracht.eu2 Basic construction of BT (rear bearing cover removed) Basic construction of BTH (rear bearing cover removed) Driving shaft Heating liquid outlet Gearing with journals Gearing with journals Housing Heating chamber Pumping chamber Housing Shaft sealing by packed gland/ Mechanical seal Stuffing-box cover Driving shaft Shaft sealing by packed gland Stuffing-box cover Transfering medium inlet or…
File type: application/pdf
Referenced at:
Gear Pumps BT, BTH Transfer Gear Pumps BT, BTH Construction KRACHT GmbH · Gewerbestr. 20 · 58791 Werdohl, Germany · fon +49(0)23 92/935-0 · fax +49(0)23 92/935 209 · mail info@kracht.eu · web www.kracht.eu2 Basic construction of BT (rear bearing cover removed) Basic construction of BTH (rear bearing cover removed) Driving shaft Heating liquid outlet Gearing with journals Gearing with journals Housing Heating chamber Pumping chamber Housing Shaft sealing by packed gland/ Mechanical seal Stuffing-box cover Driving shaft Shaft sealing by packed gland Stuffing-box cover Transfering medium inlet or…
File type: application/pdf
Referenced at:
JIS symbol Linear slide cylinder Double acting single rod type clean room specifications LCM -P73 Series Bore size: 4.5, 6, 8 Specifications Descriptions LCM -P73 Bore size mm 4.5 6 8 Actuation Double acting Working fluid Compressed air Max. working pressure MPa 0.7 Min. working pressure MPa 0.2 0.15 Withstanding pressure MPa 1.05 Ambient temperature 0 to 60 Port size M3 Stroke tolerance mm +1.00 Working piston speed mm/s 30 to 300 Cushion None Rubber cushioned Lubrication Not available Allowable energy absorption J Refer to the table on Page 1766. Stroke length Bore size (mm) Standard stroke…
File type: application/pdf
Referenced at:
ROBOT CALIBRATION WITH TCP-MEASURING INSTRUMENTS FROM CAPTRON Application Notewww.captron.com ROBOT CALIBRATION WITH TOOL-CENTER-POINT MEASURING Q U A L I T Y M A D E I N B A V A R I A Nachher Figure 1: Tool coordinate system (TCP) relative to the robot’s flange coordinate system Zflange Ztool Ytool Xtool Xflange Yflange TCP State-of-the-art robotic automation systems rely on high accuracy. Whenever harsh environments, wear, or tool changes are part of the application, repeated tool checks or recalibrations are required to maintain high accuracy and quality over time. To describe a tool in…
File type: application/pdf
Referenced at: