ROTARY JOINTS Fluid Working Pressure Range Negative Pressure Temperature Range Applicable Tube Material Air(No other gases or liquids) 0~150PSI 0~9Kgf/ (0~900kPa) -750mmHg(10Torr) 0~60 C32~140 F Polyurethane and Nylon -29.50 in Hg Application Structural Diagram Feature Specification - Used for supplying compressed air at swiveling or swinging connections. - Used for index tables and industrial robots. - Built in bearings, suitable for high-speed swiveling pneumatic connections.. Thread Size(T) Type Tube Dia( D) Metric Size Taper Pipe Thread Code 04 06 08 10 12 Dia 4 6 8 10 12 Code M5 M6 01 02…
File type: application/pdf
Referenced at:
ROTARY JOINTS Fluid Working Pressure Range Negative Pressure Temperature Range Applicable Tube Material Air(No other gases or liquids) 0~150PSI 0~9Kgf/ (0~900kPa) -750mmHg(10Torr) 0~60 C32~140 F Polyurethane and Nylon -29.50 in Hg Application Structural Diagram Feature Specification - Used for supplying compressed air at swiveling or swinging connections. - Used for index tables and industrial robots. - Built in bearings, suitable for high-speed swiveling pneumatic connections.. Thread Size(T) Type Tube Dia( D) Metric Size Taper Pipe Thread Code 04 06 08 10 12 Dia 4 6 8 10 12 Code M5 M6 01 02…
File type: application/pdf
Referenced at:
BHF BHM 112p 114p BMF 112p BMR BHMR BHWF BCM BRM 112p 113p 113p 113p 114p Main Blocks Universal Quick Universal M Thread BMM 114p Bush BUMR 114p Socket BUMM 115p Nipple BPM 115p Plug BL 115p Elbow Bulkhead Reducer Bush Universal Rc Thread Universal Branch Cap Bush SANG-A PNEUMATIC CO.,LTD. 111 M ain B locks SANG-A PNEUMATIC CO.,LTD. 110 MAIN BLOCKS Fluid Working Pressure Range Negative Pressure Temperature Range Applicable Tube Material Air(No other gases or liquids) 0~150PSI 0~9Kgf/ (0~900kPa) -750mmHg(10Torr) 0~60 C32~140 F Polyurethane and Nylon -29.50 in Hg Application Structural Diagram…
File type: application/pdf
Referenced at:
SPEED CONTROLLERS Fluid Working Pressure Range Negative Pressure Temperature Range Applicable Tube Material Air(No other gases or liquids) 0~150PSI 0~9Kgf/ (0~900kPa) 0.5Kgf/ (50kPa) 0~60 C32~140 F Polyurethane and Nylon 7.5PSI Application Structural Diagram Feature Specification - Valve used for controlling the operation speed of a driving device. - Used for movement of machines such as cylinder, pneumatic finger, etc. - Precisely permit the optimal rate of airflow for the smooth cylinder movement of driving devices. - The Compact and light body permits use in confined space. -…
File type: application/pdf
Referenced at:
page 135 2.8 Namur Valves Selected models are available for explosion hazardous environment. They are ATEX-Ex certified. Selected models are available for low temperature application. Temperature-range: - 50° C to + 50° C. For detailed information refer to chapter 2.9. Namur 1/4” also called “Namur 1” in accordance to VDI / VDE 3845. Namur 1/2” also called “Namur 2”. 2.8 page 3 Table of Contents page 10 Quick Finder for Manifold Systems 11 2.1 Mechanically Actuated Valves 2.1.1 3/2 way valves 12 2.1.1.1 BV/BR/BL 311 201 13 2.1.1.2 BV/BR/BL 311 202 14 2.1.1.3 BV/BR/BL 311 243 15 2.1.1.4…
File type: application/pdf
Referenced at:
page 11 2.1 Mechanically Actuated Valves 2.1 page 3 Table of Contents page 10 Quick Finder for Manifold Systems 11 2.1 Mechanically Actuated Valves 2.1.1 3/2 way valves 12 2.1.1.1 BV/BR/BL 311 201 13 2.1.1.2 BV/BR/BL 311 202 14 2.1.1.3 BV/BR/BL 311 243 15 2.1.1.4 BV/BR/BL 311 301 2.1.2 5/2 way valves 16 2.1.2.1 BV/BR/BL 511 201 17 2.1.2.2 BV/BR/BL 511 301 19 2.2 Valves for Panel Mounting 20 2.2.1 BA 311 201/BA 311 202/BA 311 203 BA 311 243/BA 311 301 21 2.2.2 BA 511 201/BA 511 202/BA 511 301 22 2.2.3 Ø 22mm Actuators for Panel Mounting 23 2.2.4 BH 311 401/BH 320 401/BH 311 701/BH 320 701 24…
File type: application/pdf
Referenced at:
page 33 2.4 Pilot Actuated Valves Selected models are available for explosion hazardous environment. They are ATEX-Ex certified. Selected models are available for low temperature application. Temperature-range: - 50° C to + 50° C. For detailed information refer to chapter 2.9. page 3 Table of Contents page 10 Quick Finder for Manifold Systems 11 2.1 Mechanically Actuated Valves 2.1.1 3/2 way valves 12 2.1.1.1 BV/BR/BL 311 201 13 2.1.1.2 BV/BR/BL 311 202 14 2.1.1.3 BV/BR/BL 311 243 15 2.1.1.4 BV/BR/BL 311 301 2.1.2 5/2 way valves 16 2.1.2.1 BV/BR/BL 511 201 17 2.1.2.2 BV/BR/BL 511 301 19 2.2…
File type: application/pdf
Referenced at:
SANG-A PNEUMATIC CO.,LTD. SANG-A PNEUMATIC CO.,LTD.124 125 Two -Touch Fitting TWO-TOUCH FITTING Fluid Working Pressure Range Negative Pressure Temperature Range Applicable Tube Material Air(No other gases or liquids) 0~150PSI 0~9Kgf/ (0~900kPa) -750mmHg(10Torr) 0~60 C32~140 F Polyurethane and Nylon -29.50 in Hg Application Structural Diagram Feature Specification - Nut-tightened air connector used for pneumatic piping. - Effective use at the place of vibration or rocking. - Long life-span made of plastic. - Excellent in anti-corrosion and anti-chemicals. Type Tube Dia( D) Code 04 06 08 10 12…
File type: application/pdf
Referenced at:
934 Series variation Joint / tube Miniature joint F Series Miniature type Barbed, clamp joint Joint mini-type GWJ Series Push-in joint For R screw, standard sealant is applied. Flame resistance resin is provided as standard. Joint GW Series Push-in joint For R screw, standard sealant is applied. Female joint MJ/JL Series Push-in joints for fiber tube standard type PG Series Tightening joint Can be used for copper tube. Push-in joint PP resin incorporated as standard to increase corrosion resistance Joint stainless steel type ZW Series Push-in joint Flame resistance resin Stainless steel…
File type: application/pdf
Referenced at:
27 AV LINE Raccordi Automatici in Ottone High Performance Brass Push-in Fittings High Performance Raccords Instantanés en Laiton, High Performance Messing Steckverschraubungen, High Performance I Raccordi Automatici della serie AV sono realizzati in ottone e caratterizzati da un trat- tamento superficiale di nichelatura chimica certificata NSF 51; sono ideali per l’industria alimentare e chimica con una buona resistenza agli ambienti aggressivi e alle alte temperature di lavoro. Tutti i raccordi della serie AV vengono sotto- posti a trattamento superficiale di Nichelatura chimica certificata…
File type: application/pdf
Referenced at: