ISO CONFORMED VALVE ISO conformed valve New Products PV5G/PV5/CMF Series CC-824A 1 * I /O connector * DIN terminal box Large rotation angle for wrench is provided. 10% Reduced (CKD comparison) Introducing the New Compact Easy-Use ISO Valve! New ISO-compliant valve PV5G, PV5, and CMF Series are compact, lightweight, and energy-saving, featuring greatly improved operability, life, and environmental innovations. Low wattage design 1 W Power consumption is reduced from the conventional 1.8 W to 1 W, enabling greater energy saving. A compact size is realized while improving the total performance.…
File type: application/pdf
Referenced at:
ISO CONFORMED VALVE ISO conformed valve New Products PV5G/PV5/CMF Series CC-824A 1 * I /O connector * DIN terminal box Large rotation angle for wrench is provided. 10% Reduced (CKD comparison) Introducing the New Compact Easy-Use ISO Valve! New ISO-compliant valve PV5G, PV5, and CMF Series are compact, lightweight, and energy-saving, featuring greatly improved operability, life, and environmental innovations. Low wattage design 1 W Power consumption is reduced from the conventional 1.8 W to 1 W, enabling greater energy saving. A compact size is realized while improving the total performance.…
File type: application/pdf
Referenced at:
48 FGB Series Discrete direct acting 2 port solenoid valve for dry air (special purpose valve) NC (normally closed) type Port size: Rc1/8 to Rc1/2 Common specifications Descriptions Dry air, inert gas, low vacuum (up to 1.33 x 102Pa(abs)) 0 to 1.4 (Refer to the maximum working pressure differential on the individual specifications) 2.1 (1.5 for FGB11/21) -10 to 40 (no freezing) -20 to 40 B No corrosive gas and flammable Direct acting poppet structure 0.2 or less Free IP65 or equivalent (Note 1) 1.5 2 2 3 5 3 4 7 4 5 7 10 0.28 0.55 0.55 1.2 3.1 1.2 2.1 5.7 2.1 3.1 5.7 5.5 1.0 0.6 1.4 0.6 0.15…
File type: application/pdf
Referenced at:
48 FGB Series Discrete direct acting 2 port solenoid valve for dry air (special purpose valve) NC (normally closed) type Port size: Rc1/8 to Rc1/2 Common specifications Descriptions Dry air, inert gas, low vacuum (up to 1.33 x 102Pa(abs)) 0 to 1.4 (Refer to the maximum working pressure differential on the individual specifications) 2.1 (1.5 for FGB11/21) -10 to 40 (no freezing) -20 to 40 B No corrosive gas and flammable Direct acting poppet structure 0.2 or less Free IP65 or equivalent (Note 1) 1.5 2 2 3 5 3 4 7 4 5 7 10 0.28 0.55 0.55 1.2 3.1 1.2 2.1 5.7 2.1 3.1 5.7 5.5 1.0 0.6 1.4 0.6 0.15…
File type: application/pdf
Referenced at:
48 FGB Series Discrete direct acting 2 port solenoid valve for dry air (special purpose valve) NC (normally closed) type Port size: Rc1/8 to Rc1/2 Common specifications Descriptions Dry air, inert gas, low vacuum (up to 1.33 x 102Pa(abs)) 0 to 1.4 (Refer to the maximum working pressure differential on the individual specifications) 2.1 (1.5 for FGB11/21) -10 to 40 (no freezing) -20 to 40 B No corrosive gas and flammable Direct acting poppet structure 0.2 or less Free IP65 or equivalent (Note 1) 1.5 2 2 3 5 3 4 7 4 5 7 10 0.28 0.55 0.55 1.2 3.1 1.2 2.1 5.7 2.1 3.1 5.7 5.5 1.0 0.6 1.4 0.6 0.15…
File type: application/pdf
Referenced at:
The check valves that expand applications. Contributes to improved workability and tact time. For coolants and wash water. Example of applications Nozzle for machine tool coolants Prevents fluid dripping from leading to incorrect detections of the cutting tool breakage sensor Improves discharge responsivity Cleaning equipment Fluid dripping prevention protects workpieces Improved workability Stops precisely and continues to the next process smoothly, contributing to improved workability and tact time. No check valve Check valve with nozzle Fluid dripping does not stop. Prevents fluid dripping…
File type: application/pdf
Referenced at:
The check valves that expand applications. Contributes to improved workability and tact time. For coolants and wash water. Example of applications Nozzle for machine tool coolants Prevents fluid dripping from leading to incorrect detections of the cutting tool breakage sensor Improves discharge responsivity Cleaning equipment Fluid dripping prevention protects workpieces Improved workability Stops precisely and continues to the next process smoothly, contributing to improved workability and tact time. No check valve Check valve with nozzle Fluid dripping does not stop. Prevents fluid dripping…
File type: application/pdf
Referenced at:
The check valves that expand applications. Contributes to improved workability and tact time. For coolants and wash water. Example of applications Nozzle for machine tool coolants Prevents fluid dripping from leading to incorrect detections of the cutting tool breakage sensor Improves discharge responsivity Cleaning equipment Fluid dripping prevention protects workpieces Improved workability Stops precisely and continues to the next process smoothly, contributing to improved workability and tact time. No check valve Check valve with nozzle Fluid dripping does not stop. Prevents fluid dripping…
File type: application/pdf
Referenced at:
551 M ot or v al ve E le ct ric d riv en b al l v al ve 2 , 3 p or t v al ve SAB/ SVB Explosion proof For dry air HVB/ HVL NP/NAP/ NVP PD/FAD/ PJ CVE/ CVSE CPE/ CPD Custom order Medical analysis Other G.P. systems HNB/G USB/G FAB/G FGB/G FVB FWB/G FHB FLB AB AG AP/AD CHB/G MXB/G APK/ ADK MXB/MXG (Motor valve) Motor driven ball valve 2, 3 port valve For water, hot water, air, oil, corrosive fluid and steam Water-hammering is eliminated with CKD original ball opening/closing structure. This valve is suitable for water and hot water control, oil and steam application. Even with its small size,…
File type: application/pdf
Referenced at:
551 M ot or v al ve E le ct ric d riv en b al l v al ve 2 , 3 p or t v al ve SAB/ SVB Explosion proof For dry air HVB/ HVL NP/NAP/ NVP PD/FAD/ PJ CVE/ CVSE CPE/ CPD Custom order Medical analysis Other G.P. systems HNB/G USB/G FAB/G FGB/G FVB FWB/G FHB FLB AB AG AP/AD CHB/G MXB/G APK/ ADK MXB/MXG (Motor valve) Motor driven ball valve 2, 3 port valve For water, hot water, air, oil, corrosive fluid and steam Water-hammering is eliminated with CKD original ball opening/closing structure. This valve is suitable for water and hot water control, oil and steam application. Even with its small size,…
File type: application/pdf
Referenced at: