2 2.233.1 Valves series A1 1/8”, 5/2 - 5/3, manually operated Standard executions Version Symbol Code Item 5/2 side lever, 1 position 034064 A1MA150LL 5/2 side lever, 2 positions 034063 A1MA151LL 5/3 side lever, 1 position 034062 A1MA170LL 5/3 side lever open centres, 1 position 034066 A1MA171LL 5/3 side lever pressurised centres 1 position 034065 A1MA172LL 5/3 side lever closed centres, 3 positions 034068 A1MA173LL 5/3 side lever, open centres, 3 positions 034067 A1MA174LL 5/3 side lever, pressurised centres 3 positions 034069 A1MA175LL 5/2 top lever, 2 positions 034091 A1MA151LT 5/2…
File type: application/pdf
Referenced at:
40 DEUBLIN DN B1 x B2 A C1 C2 D1 D2 E F G H1 H2 J K N NPT ø ø ø NPT 2 x 8 ¹/₄ x ¹/₂ 2117-001-105 2117-017-105 2117-018-137 G ³/₄ RH 70 38 125 194 48 19 6,4 36 22 66 ¹/₄ 81 1,5 DN B A C D E F G H J U NPT ø ø ¹/₄ 17-025-039 17-051-039 17-086-039 G ³/₈ RH 38 83,3 29 16 8 22 39 1,5 0,3 ¹/₄ 17-025-046 17-051-046 17-086-046 M16 x 2 RH 38 83,3 29 16 8 22 39 1,5 0,3 ¹/₂ 21-001-122 21-083-122 21-063-122 G ³/₄ RH 70 116 39 19 16 36 57 2 1,2 ¹/₂ 21-001-121 21-083-121 21-063-121 M22 x 1,5 RH 70 111 34 14 13 36 57 1,5 1,2 8 15 150 PSI 10 bar 2 "Hg 7 kPa 3,050 PSI 210 bar 250 RPM 250 min-1 kg kg DEUBLIN…
File type: application/pdf
Referenced at:
334 RRC GRC RV3* NHS HR LN FH100 HAP BSA2 LHA LHAG HKP HEP HCP HMF HMFB HFP HLC HGP FH500 HBL HDL HMD HJL BHE CKG CK CKA CKS CKF CKJ CKL2 CKH2 CKLB2 FJ FK Ending HLA/ HLB HLAG/ HLBG CKL2 -*-HC NCK/ SCK/FCK BHA/ BHG Standard (double acting)/O (normally open) type C (normally closed) type * Spring of 7 is not contained in standard (double acting) type. Internal structure and parts list No. 1 2 3 4 5 6 7 8 9 10 Parts name Bearing Guide rod Rod packing seal Cylinder gasket Piston packing seal Magnet Spring Master key Center guard Side cover Material Steel Alloy steel Nitrile rubber Nitrile rubber…
File type: application/pdf
Referenced at:
1.110.10 Switches ATEX Directive 2014/34/EU Technical data Item MK500A MK502A Electrical design DC PNP Connection to certified intrinsically safe circuits with the max. values U = 15 V / I = 50 mA / P = 120 mW Operating voltage 10 ÷ 30 V DC 8,2 V DC Current consumption ≤10 mA ≥ 2,2 mA Protection class III III Reverse polarity protection SI - Power-on delay time < 30 ms - Output function NO NO Voltage drop < 2,5 V - Current rating 100 mA - Short-circuit protection SI - Overload protection SI - Switching frequency 10000 Hz 2000 Hz Magnetic sensitivity 2,8 mT 2 mT Travel speed > 10 m/s > 10 m/s…
File type: application/pdf
Referenced at:
1.110.10 Switches ATEX Directive 2014/34/EU Technical data Item MK500A MK502A Electrical design DC PNP Connection to certified intrinsically safe circuits with the max. values U = 15 V / I = 50 mA / P = 120 mW Operating voltage 10 ÷ 30 V DC 8,2 V DC Current consumption ≤10 mA ≥ 2,2 mA Protection class III III Reverse polarity protection SI - Power-on delay time < 30 ms - Output function NO NO Voltage drop < 2,5 V - Current rating 100 mA - Short-circuit protection SI - Overload protection SI - Switching frequency 10000 Hz 2000 Hz Magnetic sensitivity 2,8 mT 2 mT Travel speed > 10 m/s > 10 m/s…
File type: application/pdf
Referenced at:
RELIABLERELIABLERELIABLE COM PRESSED AIR CON D EN SATE M AN AGEM EN T AN D EN ERGY SAVIN G PROD UCTS COM PRESSED AIR CON D EN SATE M AN AGEM EN T AN D EN ERGY SAVIN G PROD UCTS ENVIRONMENT SAFEGUARDCOMPACT TECHNOLOGY OIL/WATER SEPARATION PURO-CT JORC Industrial BV Pretoriastraat 28 NL-6413 NN Heerlen The Netherlands Tel: +31 (0) 45 524 24 27 Fax: +31 (0) 45 524 19 79 info@jorc.nl www.jorc.eu INDEX Chapter Content Page 1 Introduction to compressor lubrication 2 Additives and detergents 2 Compressed air condensate 3 Why install an oil/water separator 3 2 Will any oil/water separator do? 4 JORC’s…
File type: application/pdf
Referenced at:
RELIABLERELIABLERELIABLE COM PRESSED AIR CON D EN SATE M AN AGEM EN T AN D EN ERGY SAVIN G PROD UCTS COM PRESSED AIR CON D EN SATE M AN AGEM EN T AN D EN ERGY SAVIN G PROD UCTS ENVIRONMENT SAFEGUARDCOMPACT TECHNOLOGY OIL/WATER SEPARATION PURO-CT JORC Industrial BV Pretoriastraat 28 NL-6413 NN Heerlen The Netherlands Tel: +31 (0) 45 524 24 27 Fax: +31 (0) 45 524 19 79 info@jorc.nl www.jorc.eu INDEX Chapter Content Page 1 Introduction to compressor lubrication 2 Additives and detergents 2 Compressed air condensate 3 Why install an oil/water separator 3 2 Will any oil/water separator do? 4 JORC’s…
File type: application/pdf
Referenced at:
RELIABLERELIABLERELIABLE COM PRESSED AIR CON D EN SATE M AN AGEM EN T AN D EN ERGY SAVIN G PROD UCTS COM PRESSED AIR CON D EN SATE M AN AGEM EN T AN D EN ERGY SAVIN G PROD UCTS ENVIRONMENT SAFEGUARDCOMPACT TECHNOLOGY OIL/WATER SEPARATION PURO-CT JORC Industrial BV Pretoriastraat 28 NL-6413 NN Heerlen The Netherlands Tel: +31 (0) 45 524 24 27 Fax: +31 (0) 45 524 19 79 info@jorc.nl www.jorc.eu INDEX Chapter Content Page 1 Introduction to compressor lubrication 2 Additives and detergents 2 Compressed air condensate 3 Why install an oil/water separator 3 2 Will any oil/water separator do? 4 JORC’s…
File type: application/pdf
Referenced at:
RELIABLERELIABLERELIABLE COM PRESSED AIR CON D EN SATE M AN AGEM EN T AN D EN ERGY SAVIN G PROD UCTS COM PRESSED AIR CON D EN SATE M AN AGEM EN T AN D EN ERGY SAVIN G PROD UCTS ENVIRONMENT SAFEGUARDCOMPACT TECHNOLOGY OIL/WATER SEPARATION PURO-CT JORC Industrial BV Pretoriastraat 28 NL-6413 NN Heerlen The Netherlands Tel: +31 (0) 45 524 24 27 Fax: +31 (0) 45 524 19 79 info@jorc.nl www.jorc.eu INDEX Chapter Content Page 1 Introduction to compressor lubrication 2 Additives and detergents 2 Compressed air condensate 3 Why install an oil/water separator 3 2 Will any oil/water separator do? 4 JORC’s…
File type: application/pdf
Referenced at:
Motion Safety: Improving Productivity with Safety in Mind Safe Motion Control from One Source K O L L M O R G E N w w w. k o l l m o r g e n . c o m With Motion SafetyConventional Safety Productivity Gain with Motion Safety Intervention by Operator Intervention by Operator Time Pr od uc tio n Vo lu m e Kollmorgen - Your skilled partner for Safe Motion Solutions Kollmorgen’s safety systems were developed using IEC 61508 Functional Safety of Electrical/Electronic/ Programmable Electronic Safety-related Systems. They are suitable for use applications following these standards: • ISO 13894 machine…
File type: application/pdf
Referenced at: