Kinetics roller guide type precise gripping because of base jaw guides with small clearance Base jaw for fitting the workpiece specific gripper fingers Body high-tensile aluminum body with lightest possible because of hard anodizing AF105P-08,10,16 Roller guide type Back pressure sensor is available only. Small size but strong grip force Taper sliding & roller guide type Easy to mount many grippers (compact body) Drive double acting pneumatic cylinder 52 Character Gripper www.jrtfa.com Character AF105P Gripper Body Piston Packing O-Ring End Cover Plunger Pin Hinge Pin Snap Ring Master Jaw…
File type: application/pdf
Referenced at:
Digital Servoamplifier SERVOSTAR® 400 www.danahermotion.com SERVOSTAR® 400 M Intensive observation of the market and precise analysis of customers wishes is the foundation of all development. The new, digital multi-axis system SERVOSTAR® 400 is the result of this research. Thanks to years of experience in digital servo technology and fieldbus systems, we are able to offer a servo system that delivers maximum performance in minimum space at minimum cost. We give you a complete servo system: servo amplifiers, motors, and installation-ready cabling. SERVOSTAR® 400 is completely softwarecompatible…
File type: application/pdf
Referenced at:
10.18 With the suction and blowing system AS we have tried to provide the printing industry with an answer to most of their requirements regarding the management of paper during the printing process, i.e.: - The concentration of all the necessary pumps and commands on one single piece. - An ever increasing printing quality thanks to individually controlled pumps. - An increase of productivity resulting from the configuration and use of individual pumps. - Reduced machine idle state due to the pneumatic pumps based on the Venturi principle. - An improvement of the work environment thanks to the…
File type: application/pdf
Referenced at:
A A D B G C E AF AA sectional view D is pl ac em en t a ng le M1 moment D is pl ac em en t a ng le M2 moment D is pl ac em en t a ng le M3 moment D is pl ac em en t a ng le (° ) 0.025 0.02 0.015 0.005 0 Bending moment (N m) 0 0.05 0.1 0.15 0.2 0.25 0.3 LCM-4.5 LCM-6, 8 0.01D is pl ac em en t a ng le (° ) 0 Bending moment (N m) 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.02 0.03 0.04 0.05 0.06 0.07 0.08 LCM-4.5 LCM-6 LCM-8 D is pl ac em en t a ng le (° ) 0.005 0 Bending moment (N m) 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.01 0.015 0.02 0.025 LCM-4.5 LCM-6, 8 Technical data Precision of slide table…
File type: application/pdf
Referenced at:
13 DEUBLIN DN B O A C D1 D2 E F G H J K N P R S NPT NPT STD E.L.S. ø ø ø NPT 2¹/₂ 1¹/₄ 755-700-330-117+ 755-701-330-117+ G 2¹/₂ RH 178 336 381 82 38 60,3 83 208 2 108 1 NPT 308 13 20 2¹/₂ 1¹/₄ 755-700-411-117+ 755-701-411-117+ G 2¹/₂ LH 178 336 381 82 38 60,3 83 208 2 108 1 NPT 308 13 20 2¹/₂ 1¹/₂ 755-707-330-139+ 755-731-330-139+ G 2¹/₂ RH 178 336 391 82 38 60,3 83 208 2 112 G 1¹/₂ 320 45 20 2¹/₂ 1¹/₂ 755-707-411-139+ 755-731-411-139+ G 2¹/₂ LH 178 336 391 82 38 60,3 83 208 2 112 G 1¹/₂ 320 45 20 2¹/₂ 1¹/₂ 755-732-330-139+ 755-733-330-139+ G 2¹/₂ RH 178 - 391 82 38 60,3 83 208 2 112 ø 39,9 h…
File type: application/pdf
Referenced at:
VOLUMEC Valve Position Indicator 5 VOLUMEC Valve Position Indicator 5 Description Modular design VOLUMEC Indicator AVC .. A Optically AVC .. B Open /Close switches AVC .. C/CL Potentiometer AVC .. D/DL Potentiometer + o/c switches The VOLUMEC 5 valve position indicator consists of one volume counter and one indicator device. Mounted on a connecting plate, the VOLUMEC 5 carries out the functions of measuring and counting the adjustment track of hydraulically operated ship armatures. The measurement unit is seawater-resistant and suitable for being mounted on deck. The volumetrically ascertained…
File type: application/pdf
Referenced at:
VOLUMEC Valve Position Indicator 5 VOLUMEC Valve Position Indicator 5 Description Modular design VOLUMEC Indicator AVC .. A Optically AVC .. B Open /Close switches AVC .. C/CL Potentiometer AVC .. D/DL Potentiometer + o/c switches The VOLUMEC 5 valve position indicator consists of one volume counter and one indicator device. Mounted on a connecting plate, the VOLUMEC 5 carries out the functions of measuring and counting the adjustment track of hydraulically operated ship armatures. The measurement unit is seawater-resistant and suitable for being mounted on deck. The volumetrically ascertained…
File type: application/pdf
Referenced at:
VOLUMEC Valve Position Indicator 5 VOLUMEC Valve Position Indicator 5 Description Modular design VOLUMEC Indicator AVC .. A Optically AVC .. B Open /Close switches AVC .. C/CL Potentiometer AVC .. D/DL Potentiometer + o/c switches The VOLUMEC 5 valve position indicator consists of one volume counter and one indicator device. Mounted on a connecting plate, the VOLUMEC 5 carries out the functions of measuring and counting the adjustment track of hydraulically operated ship armatures. The measurement unit is seawater-resistant and suitable for being mounted on deck. The volumetrically ascertained…
File type: application/pdf
Referenced at:
HVB41 Series 427 SAB/ SVB Explosion proof For dry air HVB/ HVL NP/NAP/ NVP PD/FAD/ PJ CVE/ CVSE CPE/ CPD Custom order Medical analysis Other G.P. systems HNB/G USB/G FAB/G FGB/G FVB FWB/G FHB FLB AB AG AP/AD CHB/G MXB/G APK/ ADK S ol en oi d va lv e fo r hi gh v ac uu m Internal structure and main parts materials Dimensions and optional dimensions Coil assembly Core assembly tightening torque Plunger assembly Spring O ring Body Cushion plate SUS405 SUS403 SUS316L SUS405 FKM PET SUS304 FKM SUS303 PET 1 2 3 4 5 6 7 HVB41-8N No. Parts name Material Square terminal box HVB41-*-*- Mounting plate…
File type: application/pdf
Referenced at:
118 Manual valve for high vacuum MVB 0 Series •Formed bellows •Handle 5 6 7 Custom order Model No. Actuation Orifice MVB70 Manual ø50 Model No. Actuation Orifice MVB50 Manual ø24 MVB60 Manual ø40 •Long-life formed bellows Special, stainless steel material (ASL-350) provided. Corrosion resistance is outstanding. •Low dust generation Wetted areas (flow path) have no sliding sections that may generate particles. •Handle •Usable with back pressure The vacuum pump can be connected to either port. MVB60 MVB70MVB50 Working fluid Working pressure range Pa(abs) Maximum working differential pressure MPa…