BIBUS Parts Qty. EL-60 EL-80-15 EL-80-17 EL-100 Diaphragm 2 11 Diaphragm Holder 2 10 Nut 2 23 Valve Box & Valve 2 12 Filter Element 1 2 Magnet support jig 4 Manual 1 Magnet 1 9 Nut 2 23 Magnet 1 9 Nut 2 23 EL-60DU Driving Unit EL-60 1 EL-80-15DU Driving Unit EL-80-15 1 EL-80-17DU Driving Unit EL-80-17 1 EL-100DU Driving Unit EL-100 1 EL-60 EL-80-15 EL-80-17 EL-100 Filter Cover FILTERCOVER-EL 1 1 1 1 1 Filter Element FILTER-EL 2 1 1 1 1 Overall Cover 3 1 1 1 1 Shock Absorber 4 1 1 1 1 Holder Cover HOLDERCOVER-EL 5 1 1 1 1 Auto Stopper (48 mm, white) S-EL60,80-15,120W 1 1 Auto Stopper (46 mm,…
File type: application/pdf
Referenced at:
Kinetic pinion/toothed rack system for low tolerance transmission of drive power in one rotation movement Intake flange for connection to application specific adapter plate Body high-tensile aluminum body with lightest possible because of hard anodizing RTU-25,40,50 Finger attachable 90 swivel unit Drive double acting pneumatic cylinder Rectangular rotary unit to be able to rotate two grippers rectangularly mounted unit In case of using with series AF30 or AF46, easy to assemble into a module Internal shock absorber reduce shock at end of rotation and increase road stopping capacity Light…
File type: application/pdf
Referenced at:
DIRECTIONAL CONTROL VALVES CETOP5 CONTENTS: RH10...1 - electrical control ...................................... RH10...4 - mechanical control .................................. RH10...6 - pneumatic control ................................. RH10...7 - manual control ..................................... DVAS10-20 - automatic switch .............................. Page 1/15...7/15 8/15...9/15 10/15...11/15 12/15...13/15 14/15...15/15 1/15 GENERAL DESCRIPTION RH10...1-...F... 4/3- and 4/2- way directional control valves with solenoid operation , heavy duty construction Removable AC and DC voltage…
File type: application/pdf
Referenced at:
DIRECTIONAL CONTROL VALVES CETOP5 CONTENTS: RH10...1 - electrical control ...................................... RH10...4 - mechanical control .................................. RH10...6 - pneumatic control ................................. RH10...7 - manual control ..................................... DVAS10-20 - automatic switch .............................. Page 1/15...7/15 8/15...9/15 10/15...11/15 12/15...13/15 14/15...15/15 1/15 GENERAL DESCRIPTION RH10...1-...F... 4/3- and 4/2- way directional control valves with solenoid operation , heavy duty construction Removable AC and DC voltage…
File type: application/pdf
Referenced at:
HVB112 Series 425 SAB/ SVB Explosion proof For dry air HVB/ HVL NP/NAP/ NVP PD/FAD/ PJ CVE/ CVSE CPE/ CPD Custom order Medical analysis Other G.P. systems HNB/G USB/G FAB/G FGB/G FVB FWB/G FHB FLB AB AG AP/AD CHB/G MXB/G APK/ ADK S ol en oi d va lv e fo r hi gh v ac uu m Internal structure and main parts materials No. Parts name Material Core assembly tightening torque Plunger assembly Coil assembly Core B O ring Spring Body SUS316 SUS405 SUS405 FKM SUM22 FKM SUS304 SUS303 1 2 3 4 5 6 7 Dimensions and optional dimensions VCR joint (custom order) HVB112- 8R HVB112 Note: The DC specifications…
File type: application/pdf
Referenced at:
G D IR E C TI O N A L C O N TR O L VA LV E S G-93 InternetContact Details Before using the product, please check the guide pages at the front of this catalog. http://www.daikinpmc.com/en/ For latest information, PDF catalogs and operation manuals InternetContact Details Before using the product, please check the guide pages at the front of this catalog. http://www.daikinpmc.com/en/ For latest information, PDF catalogs and operation manuals Manually Operated Valve Features These directional control valves enable switching of the direction of fluid flow by operating the spool with the manual…
File type: application/pdf
Referenced at:
G D IR E C TI O N A L C O N TR O L VA LV E S G-93 InternetContact Details Before using the product, please check the guide pages at the front of this catalog. http://www.daikinpmc.com/en/ For latest information, PDF catalogs and operation manuals InternetContact Details Before using the product, please check the guide pages at the front of this catalog. http://www.daikinpmc.com/en/ For latest information, PDF catalogs and operation manuals Manually Operated Valve Features These directional control valves enable switching of the direction of fluid flow by operating the spool with the manual…
File type: application/pdf
Referenced at:
652 Compressed air 1.0 1.5 5 to 60 0.02 to 0.5 (0.01 to 0.2) (Note 1) 0.001 (lock sensitivity 0.004) (Note 2) 1.5 (Note 3) Push-in joint: 4, 6 Rc1/8 90 Specifications Descriptions Working fluid Max. working pressure Withstanding pressure Ambient temperature range Set pressure range Sensitivity Air consumption Port size Product weight Note 1: Values in parentheses are for low pressure. Note 2: Set pressure sensitivity for the pressure adjustment knob block's minimum spacing. Note 3: Value for secondary side setting pressure 0.1 MPa. IN-OUT GAUGE Mpa Mpa Mpa Mpa /min g RJB500 Flow characteristic…
File type: application/pdf
Referenced at:
652 Compressed air 1.0 1.5 5 to 60 0.02 to 0.5 (0.01 to 0.2) (Note 1) 0.001 (lock sensitivity 0.004) (Note 2) 1.5 (Note 3) Push-in joint: 4, 6 Rc1/8 90 Specifications Descriptions Working fluid Max. working pressure Withstanding pressure Ambient temperature range Set pressure range Sensitivity Air consumption Port size Product weight Note 1: Values in parentheses are for low pressure. Note 2: Set pressure sensitivity for the pressure adjustment knob block's minimum spacing. Note 3: Value for secondary side setting pressure 0.1 MPa. IN-OUT GAUGE Mpa Mpa Mpa Mpa /min g RJB500 Flow characteristic…
File type: application/pdf
Referenced at:
652 Compressed air 1.0 1.5 5 to 60 0.02 to 0.5 (0.01 to 0.2) (Note 1) 0.001 (lock sensitivity 0.004) (Note 2) 1.5 (Note 3) Push-in joint: 4, 6 Rc1/8 90 Specifications Descriptions Working fluid Max. working pressure Withstanding pressure Ambient temperature range Set pressure range Sensitivity Air consumption Port size Product weight Note 1: Values in parentheses are for low pressure. Note 2: Set pressure sensitivity for the pressure adjustment knob block's minimum spacing. Note 3: Value for secondary side setting pressure 0.1 MPa. IN-OUT GAUGE Mpa Mpa Mpa Mpa /min g RJB500 Flow characteristic…
File type: application/pdf
Referenced at: