76 Read the precautions on pages 7 to 12 in the introduction before use. Orifice: MMD302: Ø6.3 to Ø10 MMD402: Ø14.7 to Ø16 MMD502: Ø20 MMD34502 Series Chemical liquid manual valve Subject to Export Trade Control Ordinances *Target: MMD402 and 502 only Specifications Working fluid Fluid temperature Withstanding pressure Working pressure range (A -> B) Working pressure range (B -> A) Valve seat leakage Back pressure Ambient temperature Installation attitude Orifice Cv value Chemical liquids, pure water (Note 1) 5 to 90 (Note 2, 3) 1.2 0 to 0.4 0 to 0.4 0 (at, water pressure) 0 to 0.4 0 to 60…
File type: application/pdf
Referenced at:
Vertretungen international und national, siehe hintere Ausklappseite / See the fold-out page at the back for international and national agents / Pour les agences internationales et nationales, voir la dernière page rabattable 04 Näherungsschal ter Magnet ic switches Interrupteurs magnét iques à contact Reed Flachschal ter Sur face mount swi tches Interrupteurs p la ts 143…147 Eisennäherungsschal ter Stee l sens ing prox imi ty swi tches Interrupteurs act ionnés par métaux magn. 148 Rohrschal ter Cy l indr ica l prox imi ty swi tches Interrupteurs cy l indr iques 149…153 Schl i tzschal ter Vane…
File type: application/pdf
Referenced at:
98 www.sensopart.com HIGHLIGHTS OF VISOR® SOLAR SENSOR • Simple integration • Precise position detection • Detection of Edge defects • Detection of holes • Transport belts can be masked via software • Short cycle time from 60 ms • Reliable operation, even in daylight • No backlight necessary • Low space requirement: operating distance from 360 mm VISOR® Solar sensor for inspecting solar cells Focusing on what matters The VISOR® Solar sensor operates accu- rately and reliably even in fast-cycle pro- cesses. The VISOR® Solar sensor measures every wafer or cell and thus detects even mini- mal…
File type: application/pdf
Referenced at:
98 www.sensopart.com HIGHLIGHTS OF VISOR® SOLAR SENSOR • Simple integration • Precise position detection • Detection of Edge defects • Detection of holes • Transport belts can be masked via software • Short cycle time from 60 ms • Reliable operation, even in daylight • No backlight necessary • Low space requirement: operating distance from 360 mm VISOR® Solar sensor for inspecting solar cells Focusing on what matters The VISOR® Solar sensor operates accu- rately and reliably even in fast-cycle pro- cesses. The VISOR® Solar sensor measures every wafer or cell and thus detects even mini- mal…
File type: application/pdf
Referenced at:
98 www.sensopart.com HIGHLIGHTS OF VISOR® SOLAR SENSOR • Simple integration • Precise position detection • Detection of Edge defects • Detection of holes • Transport belts can be masked via software • Short cycle time from 60 ms • Reliable operation, even in daylight • No backlight necessary • Low space requirement: operating distance from 360 mm VISOR® Solar sensor for inspecting solar cells Focusing on what matters The VISOR® Solar sensor operates accu- rately and reliably even in fast-cycle pro- cesses. The VISOR® Solar sensor measures every wafer or cell and thus detects even mini- mal…
File type: application/pdf
Referenced at:
Transfer Gear Pumps KF 4/125...KF 6/730 with magnetic coupling KRACHT GmbH · Gewerbestr. 20 · 58791 Werdohl, Germany · fon +49(0)23 92/935-0 · fax +49(0)23 92/935 209 · mail info@kracht.eu · web www.kracht.eu2 Construction Transfer Gear Pumps KF 4/125...KF 6/730 with magnetic coupling 1 Housing 2 Flange mounting cover 3 Drive shaft 4 Gearing 5 End cover 6 Plain bearing bush 7 Outboard bearing 8 Adapter flange 9 Inner rotor 10 Outer rotor 11 Split case 12 Flange hub 13 Bell housing 14 Driven motor 15 O-Ring Function Conventional sealing gaskets are pushed to their limits with different…
File type: application/pdf
Referenced at:
Transfer Gear Pumps KF 4/125...KF 6/730 with magnetic coupling KRACHT GmbH · Gewerbestr. 20 · 58791 Werdohl, Germany · fon +49(0)23 92/935-0 · fax +49(0)23 92/935 209 · mail info@kracht.eu · web www.kracht.eu2 Construction Transfer Gear Pumps KF 4/125...KF 6/730 with magnetic coupling 1 Housing 2 Flange mounting cover 3 Drive shaft 4 Gearing 5 End cover 6 Plain bearing bush 7 Outboard bearing 8 Adapter flange 9 Inner rotor 10 Outer rotor 11 Split case 12 Flange hub 13 Bell housing 14 Driven motor 15 O-Ring Function Conventional sealing gaskets are pushed to their limits with different…
File type: application/pdf
Referenced at:
GEM 20 TAPmaster -13830 min 420 min-1 M 20 S D40 ● Gewindeschneideinheit mit mechanischem Vorschub ▲ Tapping unit with integrated leadscrew ■ Unité de taraudage avec avance mécanique ● Technische Daten Gesamthub 100 mm Gewindeschneidleistung M 20 / 600 N/mm2 Gewindesteigung min. 0,4 – max. 2,5 Übertragbares Drehmoment max. 80 Nm Drehzahlbereich bei 50 Hz 420 –1440 min-1 Induktiver Endschalter 20–250 V AC/DC Bremsmotor bei 50 Hz 1,5 kW / 1435 min-1 Gewicht / Farbe 54 kg / RAL 5012 ▲ Technical Data Total stroke 100 mm Tapping capacity M 20 / 600 N/mm2 Thread pitch min. 0.4 – max. 2.5…
File type: application/pdf
Referenced at:
516 Electro pneumatic regulator (solenoid valve type small) EVS Series JIS symbol • Chemical liquids discharge controls • Fine small position control Bellows AP R CAD DATA AVAILABLE. Specifications Descriptions EVS100 EVS500 Working fluid Max. working pressure Min. working pressure Withstanding pressure Control pressure range Power voltage Current consumption Input signal (input impedance ) How to wire Insulation resistance Withstand voltage Hysteresis Linearity Resolution Repeatability Temperature characteristics Max. flow rate (ANR) Step response Ambient temperature Fluid temperature…
File type: application/pdf
Referenced at:
98 Read the precautions on pages 7 to 12 in the introduction before use. Metal free design with flow rate adjustment and closing functions MMD20·MMD30·MMD40 Series Chemical liquid manual valve Subject to Export Trade Control Ordinances *Target: Valves with Ø12 or larger orifice Specifications Internal structure and parts list Working fluid Fluid temperature Withstanding pressure Working pressure range Valve seat leakage Ambient temperature Installation attitude Connection (Note 1) Orifice Cv value Chemical liquids, pure water, N2 gas, air 5 to 60 (5 to 90) (Note 2) 1.4 0 (at, water pressure) 0…
File type: application/pdf
Referenced at: