NEEDLE VALVE WITH ADJUSTING DIAL Needle valve with adjusting dial Easy to read flow adjustment/control achieved. DVL Series CC-860A New Product DVL Series Realizing visible flow rate adjustment and control The needle valve with dial DVL-S and DVL-N uses a rotary needle valve with linear flow properties, and numerically indicates speed with a dial. Anyone can easily adjust cylinder speed and flow accurately and with good reproducibility using this needle valve. Use as a speed controller The standard type has a built-in check valve, and can be used as a speed adjustment valve or vacuum break…
File type: application/pdf
Referenced at:
ISO CONFORMED VALVE ISO conformed valve New Products PV5G/PV5/CMF Series CC-824A 1 * I /O connector * DIN terminal box Large rotation angle for wrench is provided. 10% Reduced (CKD comparison) Introducing the New Compact Easy-Use ISO Valve! New ISO-compliant valve PV5G, PV5, and CMF Series are compact, lightweight, and energy-saving, featuring greatly improved operability, life, and environmental innovations. Low wattage design 1 W Power consumption is reduced from the conventional 1.8 W to 1 W, enabling greater energy saving. A compact size is realized while improving the total performance.…
File type: application/pdf
Referenced at:
ISO CONFORMED VALVE ISO conformed valve New Products PV5G/PV5/CMF Series CC-824A 1 * I /O connector * DIN terminal box Large rotation angle for wrench is provided. 10% Reduced (CKD comparison) Introducing the New Compact Easy-Use ISO Valve! New ISO-compliant valve PV5G, PV5, and CMF Series are compact, lightweight, and energy-saving, featuring greatly improved operability, life, and environmental innovations. Low wattage design 1 W Power consumption is reduced from the conventional 1.8 W to 1 W, enabling greater energy saving. A compact size is realized while improving the total performance.…
File type: application/pdf
Referenced at:
Pressure Gauges Hydraulic Testers Oil Analysis Equipment Catalogue 8 STAUFF Diagtronics Please note: Unless otherwise stated, all data and figures in this product catalogue are approximate values and are only valid as references, which are not binding (also in respect to any third parties’ rights of protection) and thus do not release the customer / user from checking and testing the suitability of the products for the foreseen purposes. Therefore, data and figures can only be used in a limited sense for construction purposes. The application of the products is beyond the control possibilities…
File type: application/pdf
Referenced at:
Pressure Gauges Hydraulic Testers Oil Analysis Equipment Catalogue 8 STAUFF Diagtronics Please note: Unless otherwise stated, all data and figures in this product catalogue are approximate values and are only valid as references, which are not binding (also in respect to any third parties’ rights of protection) and thus do not release the customer / user from checking and testing the suitability of the products for the foreseen purposes. Therefore, data and figures can only be used in a limited sense for construction purposes. The application of the products is beyond the control possibilities…
File type: application/pdf
Referenced at:
Hydrogen Compatible Pressure Transmitter Genspec®GS4200H Materials used in the manufacture of the Hydrogen range have been tested based on ISO 11114-2:2017 in accordance to the European Regulations EC 79/2009 and EU 406/2010 to determine an "embrittlement index" of the material when placed in a saturated environment over an extended period of time. Results have provided a Pass rating to the compatibility of the specialist Titanium Alloy of the range against Hydrogen. GENSPEC© GS4200H Hydrogen Pressure Transmitter • Compatible for use within Hydrogen based environment • Silicon-on-Sapphire…
File type: application/pdf
Referenced at:
Hydrogen Compatible Pressure Transmitter Genspec®GS4200H Materials used in the manufacture of the Hydrogen range have been tested based on ISO 11114-2:2017 in accordance to the European Regulations EC 79/2009 and EU 406/2010 to determine an "embrittlement index" of the material when placed in a saturated environment over an extended period of time. Results have provided a Pass rating to the compatibility of the specialist Titanium Alloy of the range against Hydrogen. GENSPEC© GS4200H Hydrogen Pressure Transmitter • Compatible for use within Hydrogen based environment • Silicon-on-Sapphire…
File type: application/pdf
Referenced at:
NS series RFID safety switches with lock 1 NS D4AZ1SMK-F41 NS D4AZ1SMK-F41 NS D4AZ1SMK-F41 ST DD310MK-D1TNS D4AZ1SMK-F41 ST DD310MK-D1TNG 2D1D411A-F31 HX BEE1 HX BEE1 NS series switches NS series RFID safety switches with lock These switches are used mainly on machines where the hazardous conditions persist even after the machine has been switched off. Mechanical parts such as pulleys, saw blades, etc., could continue to move after the machine is switched off. Thus, the switches can also be used if individual guards are only to be opened under certain conditions. Versions with mode 1 and 3…
File type: application/pdf
Referenced at:
Balancing Unit BBS Series CC-960A Lightly supporting heavy objects just with air Balancing Unit BBS Series Move objects weighing up to 200 kg effortlessly! Balancing Unit BBS-A BBS-O Force of 5 kg or less move objects weighing up to 200 kg! Ensure personnel safety at sites where heavy objects are handled. No more inching along! Objects glide as if guided by hand. Flexibly handle changes in weight (without adjustment) Even if weight changes with the transported workpiece, these changes are automatically recognized so a suitable balance is maintained. (BBS-A type) Balance immediately after air…
File type: application/pdf
Referenced at:
Part name Model No. Layout position Quantity 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Wiring block (Pages 576, 577) N4G1R-T 50 ○ 1 Valve block with solenoid valve (page 572) N4GD1 1 0R- C4 ○ ○ 2 N4GD1 2 0R- C6 ○ 1 N4GD1 3 0R- C4 ○ 1 N4GD1 0R- N4GD1 0R- N4GD1 0R- N3GD1 1 0R- C4 ○ ○ ○ 3 N3GD1 0R- Valve block with masking plate (Page 572) N4GA1R-MP N4GA1R-MPS N4GA1R-MPD ○ 1 Supply and exhaust block (page 574) N4G1R-Q - 8L ○ ○ 2 N4G1R-Q - N4G1R-Q - Partition block (page 575) N4G1R-S A ○ 1 N4G1R-S N4G1R-S End block (page 574) N4G1R-E R ○ 1 N4G1R-E Mounting…
File type: application/pdf
Referenced at: