Transfer Gear Pumps KF 1/4 -- KF 1/24 coated Gear Pumps KF 1/4 -- KF 1/24 coated KRACHT GmbH · Gewerbestr. 20 · 58791 Werdohl, Germany · Phone +49(0)23 92 /935-0 · Fax +49(0)23 92 /935 209 · www.kracht-hydraulik.de · info@kracht-hydraulik.de 3 Content Description, Construction . . . . . . . . . . . . . . . . . . . . . 4 Characteristics and Materials . . . . . . . . . . . . . . . . . . . 5 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Discharge Flow, Power Input . . . . . . . . . . . . . . . . . . . 6 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . .…
File type: application/pdf
Referenced at:
Clamping modules Three-Pivot-Finger Gripper 32 Product Catalog 06-2008 Dimensions with mounting flange with installation bracket 4 x Bolt holes Pivoting range max. 180° Thread for stop screw End pos. control 4 x Fastening thread 2 x Connections for air and exhaust also for CW or CCW rotation Housing vent 4 x Long bolt holes The Three-Pivot-Finger Gripper The pivot fingers are arranged 120° apart and execute rotational movements up to a max. of 180°. Extremely large clamping strokes can be traversed with the corresponding length of clamping jaws. The clamping jaws can be changed over with just…
File type: application/pdf
Referenced at:
13 120/217 ED 1/16 FV7 FIXED DISPLACEMENT VANE PUMPS SERIES 10 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS 13 120/217 ED PUMP SIZE (SINGLE) FV7B FV7D Displacement range cm3/rev 5.8 ÷ 50 44 ÷ 137.5 Flow rate range (at 1500 rpm - 0 bar) l/min 8.7 ÷ 75 66 ÷ 206 Operating pressure bar 320 250 Rotation speed (max) rpm 3600 3000 Rotation direction clockwise or anticlockwise Loads on shaft see diagrams Hydraulic connections SAE J518 SAE J518 Mounting flange SAE J744 B or ISO 3019-2 SAE J744 C or ISO 3019-2 Mass (empty single pump) kg 23 26 — The FV7 pumps are fixed displacement vane pumps, with…
File type: application/pdf
Referenced at:
13 120/217 ED 1/16 FV7 FIXED DISPLACEMENT VANE PUMPS SERIES 10 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS 13 120/217 ED PUMP SIZE (SINGLE) FV7B FV7D Displacement range cm3/rev 5.8 ÷ 50 44 ÷ 137.5 Flow rate range (at 1500 rpm - 0 bar) l/min 8.7 ÷ 75 66 ÷ 206 Operating pressure bar 320 250 Rotation speed (max) rpm 3600 3000 Rotation direction clockwise or anticlockwise Loads on shaft see diagrams Hydraulic connections SAE J518 SAE J518 Mounting flange SAE J744 B or ISO 3019-2 SAE J744 C or ISO 3019-2 Mass (empty single pump) kg 23 26 — The FV7 pumps are fixed displacement vane pumps, with…
File type: application/pdf
Referenced at:
13 120/217 ED 1/16 FV7 FIXED DISPLACEMENT VANE PUMPS SERIES 10 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS 13 120/217 ED PUMP SIZE (SINGLE) FV7B FV7D Displacement range cm3/rev 5.8 ÷ 50 44 ÷ 137.5 Flow rate range (at 1500 rpm - 0 bar) l/min 8.7 ÷ 75 66 ÷ 206 Operating pressure bar 320 250 Rotation speed (max) rpm 3600 3000 Rotation direction clockwise or anticlockwise Loads on shaft see diagrams Hydraulic connections SAE J518 SAE J518 Mounting flange SAE J744 B or ISO 3019-2 SAE J744 C or ISO 3019-2 Mass (empty single pump) kg 23 26 — The FV7 pumps are fixed displacement vane pumps, with…
File type: application/pdf
Referenced at:
Kinetics Base jaw for fitting the work -piece specific gripper fingers Body Drive double acting pneumatic cylinder high-tensile aluminum body with lightest possible because of hard anodizing AF02-16,20,30,40,63 Rack & pinion type Positioning for magnetic sensor of sensor Rack & pinion type High gripping forces by the structure of synchronized dual piston Magnetic sensor is available for open-close sensing pinion / toothed rack system, centric gripping 36 Gripper www.jrtfa.com Character AF02 37 Exploded view www.jrtfa.com Gripper Body Stopper Ring Rod Packing Damper Ring Piston Packing Piston…
File type: application/pdf
Referenced at:
Kinetics Base jaw for fitting the work -piece specific gripper fingers Body Drive double acting pneumatic cylinder high-tensile aluminum body with lightest possible because of hard anodizing AF02-16,20,30,40,63 Rack & pinion type Positioning for magnetic sensor of sensor Rack & pinion type High gripping forces by the structure of synchronized dual piston Magnetic sensor is available for open-close sensing pinion / toothed rack system, centric gripping 36 Gripper www.jrtfa.com Character AF02 37 Exploded view www.jrtfa.com Gripper Body Stopper Ring Rod Packing Damper Ring Piston Packing Piston…
File type: application/pdf
Referenced at:
Kinetics Base jaw for fitting the work -piece specific gripper fingers Body Drive double acting pneumatic cylinder high-tensile aluminum body with lightest possible because of hard anodizing AF02-16,20,30,40,63 Rack & pinion type Positioning for magnetic sensor of sensor Rack & pinion type High gripping forces by the structure of synchronized dual piston Magnetic sensor is available for open-close sensing pinion / toothed rack system, centric gripping 36 Gripper www.jrtfa.com Character AF02 37 Exploded view www.jrtfa.com Gripper Body Stopper Ring Rod Packing Damper Ring Piston Packing Piston…
File type: application/pdf
Referenced at:
16 200/117 ED 1/20 — The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications with open circuits and intermediate pressures. — They are available in seven nominal sizes, with displacements of 8, 16, 22, 36, 46, 70 and 100 cm3/rev. — The pump flow rate is proportional to the rotation speed and to the angle of the swash plate, which can be continuously modulated. The maximum and minimum angle can be limited mechanically via suitable regulating screws. — They are usually supplied with a SAE J744 2-hole flange and a SAE J744 cylindrical with key…
File type: application/pdf
Referenced at:
16 200/117 ED 1/20 — The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications with open circuits and intermediate pressures. — They are available in seven nominal sizes, with displacements of 8, 16, 22, 36, 46, 70 and 100 cm3/rev. — The pump flow rate is proportional to the rotation speed and to the angle of the swash plate, which can be continuously modulated. The maximum and minimum angle can be limited mechanically via suitable regulating screws. — They are usually supplied with a SAE J744 2-hole flange and a SAE J744 cylindrical with key…
File type: application/pdf
Referenced at: