CC-893A Guided compact cylinder SSG Series GUIDED COMPACT CYLINDER SSG SERIES Eliminate bothersome design and assembly New product 1 Safety precautions Always read this section before starting use. When designing and manufacturing a device using CKD products, the manufacturer is obligated to check that device safety mechanism, pneumatic control circuit, or water control circuit and the system operated by electrical control that controls the devices is secured. It is important to select, use, handle, and maintain the product appropriately to ensure that the CKD product is used safely. Observe…
File type: application/pdf
Referenced at:
CC-893A Guided compact cylinder SSG Series GUIDED COMPACT CYLINDER SSG SERIES Eliminate bothersome design and assembly New product 1 Safety precautions Always read this section before starting use. When designing and manufacturing a device using CKD products, the manufacturer is obligated to check that device safety mechanism, pneumatic control circuit, or water control circuit and the system operated by electrical control that controls the devices is secured. It is important to select, use, handle, and maintain the product appropriately to ensure that the CKD product is used safely. Observe…
File type: application/pdf
Referenced at:
CC-893A Guided compact cylinder SSG Series GUIDED COMPACT CYLINDER SSG SERIES Eliminate bothersome design and assembly New product 1 Safety precautions Always read this section before starting use. When designing and manufacturing a device using CKD products, the manufacturer is obligated to check that device safety mechanism, pneumatic control circuit, or water control circuit and the system operated by electrical control that controls the devices is secured. It is important to select, use, handle, and maintain the product appropriately to ensure that the CKD product is used safely. Observe…
File type: application/pdf
Referenced at:
CC-893A Guided compact cylinder SSG Series GUIDED COMPACT CYLINDER SSG SERIES Eliminate bothersome design and assembly New product 1 Safety precautions Always read this section before starting use. When designing and manufacturing a device using CKD products, the manufacturer is obligated to check that device safety mechanism, pneumatic control circuit, or water control circuit and the system operated by electrical control that controls the devices is secured. It is important to select, use, handle, and maintain the product appropriately to ensure that the CKD product is used safely. Observe…
File type: application/pdf
Referenced at:
Innovation by tradition Innovation aus Tradition L’innovation par tradition “The machine industry is our core line. Thanks to quality and performance, we’ll continue to consolidate and expand our successful positioning on the industrial niche markets.” «Die Maschinenindustrie ist unser Kerngeschäft. Durch Qualität und Leistung werden wir unsere erfolgreiche Position in industriellen Nischenmärkten weiter festigen und ausbauen.» « L’industrie des machines est notre activité principale. Nous allons continuer à renforcer et à développer avec succès notre position sur les marchés de niches…
File type: application/pdf
Referenced at:
Innovation by tradition Innovation aus Tradition L’innovation par tradition “The machine industry is our core line. Thanks to quality and performance, we’ll continue to consolidate and expand our successful positioning on the industrial niche markets.” «Die Maschinenindustrie ist unser Kerngeschäft. Durch Qualität und Leistung werden wir unsere erfolgreiche Position in industriellen Nischenmärkten weiter festigen und ausbauen.» « L’industrie des machines est notre activité principale. Nous allons continuer à renforcer et à développer avec succès notre position sur les marchés de niches…
File type: application/pdf
Referenced at:
6 Read the precautions on pages 7 to 12 in the introduction before use. AMD01232 Series Air-operated valve for chemical liquids Special PPS enables standard types to be used with hydrofluoric acids. Orifice: Ø3 to Ø4 Working fluid Fluid temperature Withstanding pressure Working pressure range (A —> B) Working pressure range (B —> A) Valve seat leakage Back pressure Ambient temperature Frequency Installation attitude Connection Orifice Cv value Operation section ˚C MPa MPa MPa cm3/min MPa ˚C Operation pressure range MPa Operation pressure connection port Specifications Pure water, chemical…
File type: application/pdf
Referenced at:
6 Read the precautions on pages 7 to 12 in the introduction before use. AMD01232 Series Air-operated valve for chemical liquids Special PPS enables standard types to be used with hydrofluoric acids. Orifice: Ø3 to Ø4 Working fluid Fluid temperature Withstanding pressure Working pressure range (A —> B) Working pressure range (B —> A) Valve seat leakage Back pressure Ambient temperature Frequency Installation attitude Connection Orifice Cv value Operation section ˚C MPa MPa MPa cm3/min MPa ˚C Operation pressure range MPa Operation pressure connection port Specifications Pure water, chemical…
File type: application/pdf
Referenced at:
6 Read the precautions on pages 7 to 12 in the introduction before use. AMD01232 Series Air-operated valve for chemical liquids Special PPS enables standard types to be used with hydrofluoric acids. Orifice: Ø3 to Ø4 Working fluid Fluid temperature Withstanding pressure Working pressure range (A —> B) Working pressure range (B —> A) Valve seat leakage Back pressure Ambient temperature Frequency Installation attitude Connection Orifice Cv value Operation section ˚C MPa MPa MPa cm3/min MPa ˚C Operation pressure range MPa Operation pressure connection port Specifications Pure water, chemical…
File type: application/pdf
Referenced at:
Transfer Gear Pumps BT, BTH Transfer Gear Pumps BT, BTH Construction KRACHT GmbH · Gewerbestr. 20 · 58791 Werdohl, Germany · fon +49(0)23 92/935-0 · fax +49(0)23 92/935 209 · mail info@kracht.eu · web www.kracht.eu2 Basic construction of BT (rear bearing cover removed) Basic construction of BTH (rear bearing cover removed) Driving shaft Heating liquid outlet Gearing with journals Gearing with journals Housing Heating chamber Pumping chamber Housing Shaft sealing by packed gland/ Mechanical seal Stuffing-box cover Driving shaft Shaft sealing by packed gland Stuffing-box cover Transfering medium…
File type: application/pdf
Referenced at: