Rodless cylinder SRL3 Series New Products Features Specifications (double acting standard type) Note 1: Piston speed used with common port piping differs with the stroke. Contact CKD for details. Descriptions SRL3 Bore size mm ø25 ø32 ø40 ø50 ø63 Actuation Double acting Working fluid Compressed air Max. working pressure MPa 0.7 Min. working pressure MPa 0.1 0.05 Withstanding pressure MPa 1.05 Ambient temperature °C 5 to 60 Port size Rc1/8 Rc1/4 Rc3/8 Stroke tolerance mm (to 1000), (to 3000), (to 5000) Working piston speed mm/s 50 to 2000 (with standard port piping) (Note 1) Cushion Air cushion…
File type: application/pdf
Referenced at:
Rodless cylinder SRL3 Series New Products Features Specifications (double acting standard type) Note 1: Piston speed used with common port piping differs with the stroke. Contact CKD for details. Descriptions SRL3 Bore size mm ø25 ø32 ø40 ø50 ø63 Actuation Double acting Working fluid Compressed air Max. working pressure MPa 0.7 Min. working pressure MPa 0.1 0.05 Withstanding pressure MPa 1.05 Ambient temperature °C 5 to 60 Port size Rc1/8 Rc1/4 Rc3/8 Stroke tolerance mm (to 1000), (to 3000), (to 5000) Working piston speed mm/s 50 to 2000 (with standard port piping) (Note 1) Cushion Air cushion…
File type: application/pdf
Referenced at:
11 100/117 ED 1/16 GP EXTERNAL GEAR PUMPS SERIES 20 HYDRAULIC SYMBOL OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS GP PUMP SIZE GP1 GP2 GP3 Displacement range cm3/rev 1.3 ÷ 9.1 7 ÷ 27.9 20.7 ÷ 87.6 Flow rate and operating pressures see table 3 - Performances Rotation speed see table 3 - Performances Rotation direction clockwise, anticlockwise or reversible (seen from the shaft side) Loads on the shaft radial and axial load are not allowed Max torque applicable to the shaft see paragraph 14.1 Hydraulic connection flanged fittings (see paragraph 16) Type of mounting 4 hole flange - rectangular…
File type: application/pdf
Referenced at:
11 100/117 ED 1/16 GP EXTERNAL GEAR PUMPS SERIES 20 HYDRAULIC SYMBOL OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS GP PUMP SIZE GP1 GP2 GP3 Displacement range cm3/rev 1.3 ÷ 9.1 7 ÷ 27.9 20.7 ÷ 87.6 Flow rate and operating pressures see table 3 - Performances Rotation speed see table 3 - Performances Rotation direction clockwise, anticlockwise or reversible (seen from the shaft side) Loads on the shaft radial and axial load are not allowed Max torque applicable to the shaft see paragraph 14.1 Hydraulic connection flanged fittings (see paragraph 16) Type of mounting 4 hole flange - rectangular…
File type: application/pdf
Referenced at:
11 100/117 ED 1/16 GP EXTERNAL GEAR PUMPS SERIES 20 HYDRAULIC SYMBOL OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS GP PUMP SIZE GP1 GP2 GP3 Displacement range cm3/rev 1.3 ÷ 9.1 7 ÷ 27.9 20.7 ÷ 87.6 Flow rate and operating pressures see table 3 - Performances Rotation speed see table 3 - Performances Rotation direction clockwise, anticlockwise or reversible (seen from the shaft side) Loads on the shaft radial and axial load are not allowed Max torque applicable to the shaft see paragraph 14.1 Hydraulic connection flanged fittings (see paragraph 16) Type of mounting 4 hole flange - rectangular…
File type: application/pdf
Referenced at:
654 Block manifold compact direct operating precision regulator MNRJB500 Series Mix manifold of RJB500/RB500 Series Port size: push-in joint 4, 6, 8 JIS symbol Flow characteristic MNRJB500A-**C64 MNRJB500A-**C86 MNRJB500B-**C4 MNRJB500B-**C6 Pressure characteristic Compressed air 0.8 1.2 5 to 60 0.02 to 0.5 (0.01 to 0.2) (Note 1) 0.001 (lock sensitivity 0.004) (Note 2) 1.5 (Note 3) Push-in joint: 4, 6 Rc1/8 Push-in joint 6, 8 Push-in joint 4, 6 Specifications Descriptions Working fluid Max. working pressure Withstanding pressure Ambient temperature range Set pressure range Sensitivity Air…
File type: application/pdf
Referenced at:
348 4GA/B M4GA/B MN4GA/B W4GA/B2 W4GB4 4TB 4SA/B0 4SA/B1 4KA/B 4F 3MA/B0 3PA/B P/M/B 4F*0E SKH 4L2-4/ LMF0 MN3S0 MN4S0 MN3E0 MN4E0 4GA/B (Master) PV5/ CMF PV5G/ CMF NP/NAP/ NVP HMV HSV PCD/ FS/FD Ending 2QV 3QV Discrete master valve, manifold (metal base) Sub-base porting 4GB1/2/3 Series Applicable cylinder bore size: ø20 to ø100 Sub-base porting (discrete, manifold) Port No. 5 port 4GB111 4GB121 4GB131 4GB211 4GB221 4GB231 4GB311 4GB321 4GB331 M4GB111 M4GB121 M4GB131 M4GB211 M4GB221 M4GB231 M4GB311 M4GB321 M4GB331 2-position single 2-position double 3-position 2-position single 2-position…
File type: application/pdf
Referenced at:
Variation Model no. JIS symbol Bore size (mm) Double acting single rod type LCM 4.5 6 8 Double acting stroke adjustable type (extended) LCM-P 4.5 6 8 Double acting stroke adjustable type (extended/retracted) LCM-R 4.5 6 8 Double acting side installation type LCM-A 4.5 6 8 Double acting single rod type clean room specifications LCM-P73 4.5 6 8 : Standard : Option : Not available Standard stroke length (mm) Option S w itc h P ag e W ith b uf fe r W ith m ag ne t M ag ne t + w ith s w itc h ra il D ow el p in a tta ch ed 5 10 15 20 B M F J* 1770 1780 1788 1796 1808 Linear slide cylinder LCM…
File type: application/pdf
Referenced at:
Two-Way Ball Valves Multi-Way Ball Valves Catalogue 6 STAUFF Valves Flow Control and Check Valves Gauge Isolator Valves Please note: Unless otherwise stated, all data and figures in this product catalogue are approximate values and are only valid as references, which are not binding (also in respect to any third parties’ rights of protection) and thus do not release the customer / user from checking and testing the suitability of the products for the foreseen purposes. Therefore, data and figures can only be used in a limited sense for construction purposes. The application of the products is…
File type: application/pdf
Referenced at:
Two-Way Ball Valves Multi-Way Ball Valves Catalogue 6 STAUFF Valves Flow Control and Check Valves Gauge Isolator Valves Please note: Unless otherwise stated, all data and figures in this product catalogue are approximate values and are only valid as references, which are not binding (also in respect to any third parties’ rights of protection) and thus do not release the customer / user from checking and testing the suitability of the products for the foreseen purposes. Therefore, data and figures can only be used in a limited sense for construction purposes. The application of the products is…
File type: application/pdf
Referenced at: