266 Individual specifications Model no. Descriptions Port size Orifice (mm) Min. working pressure diff. (MPa) Rated voltage Max. working pressure diff. (MPa) Apparent power (VA) Power consumption (W) Air AC DC AC DC AC DC AC 50Hz 60Hz50Hz60Hz Water, kerosene Oil (20 mm2/s) Steam Holding Starting AC 50/60Hz DC Mass (kg) APK11-8A APK11-10A APK11-15A APK11-20A APK11-25A Rc1/4 Rc3/8 Rc1/2 Rc3/4 Rc1 12 12 16 23 28 0 1 0.7 0.6 1 0.7 0.6 24 32 19 26 61 123 54 106 10/8 13/11 14 20 0.7 1 0.6 0.5 100 VAC 50/60Hz 110 VAC 60Hz 200 VAC 50/60Hz 220 VAC 60Hz 12 VDC 24 VDC 48 VDC 100 VDC 0.7 0.7 1.0 1.3 1.7…
File type: application/pdf
Referenced at:
7007 ECOLOC 7009 ECOLOC 7110 ECOLOC 7003 ECOLOC 7005 ECOLOC 7004 ECOLOC 7006 ECOLOC 7002 ECOLOC Katalog/Catalogue Eco-Power! 24ECOLOC_Rev_15-11-07.qxd:ECOLOC 24seiter D-GB 22.11.2007 15:01 Uhr Seite 1 Immer da, wo mit „spitzer Feder” gerechnet werden muss, bietet RINGFEDER® mit der neuen Produktlinie ECOLOC eine effiziente Alternative. So wird es möglich, auch im Bereich der Standard-Massenanwendungen RINGFEDER®-Markenware kosten- günstig einzusetzen. Produkt- und fertigungsoptimierte Prozesse gewährleisten ein hohes Maß an Wirtschaftlichkeit. RINGFEDER®, always there when precise calculations…
File type: application/pdf
Referenced at:
www.suco.de 50 Vacuum switches 0150 / 0151 Technical data Type: 0150 0151 Voltage: max. 250 V max. 42 V Contact rating: see table below* ≤ 4 A / 100 VA Temperature stability: -20 °C – +100 °C -5 °C – +120 °C Switching frequency: 200 / min. Mechanical life expectancy: 106 cycles Pressure rise rate: ≤ 1 bar/ms Vibration resistance: 10 g / 5 – 200 Hz sine-wave Shock resistance: 294 m/s2; 14 ms half-sine-wave Body material: aluminium brass Degree of protection: IP65 socket device fitted IP65, terminals IP00 Weight in grams: approx. 270 g approx. 140 g *0150 Electrical values (for technical…
File type: application/pdf
Referenced at:
Gear Type Flow Meter VC PULSE 2 KRACHT GmbH · Gewerbestr. 20 · 58791 Werdohl, Germany · Phone +49 23 92.935-0 · Fax +49 23 92.935 209 · Email info@kracht.eu · Web www.kracht.eu Gear Type Flow Meter VC PULSE Description C Product Characteristics • Selectable high measurement value resolution • Viscosity-independent measurements made in the frame of the stated ranges • Low pressure drop • Highly-dynamic measurements • High compression strength • Low noise emission • Highly-accurate measurements with outstanding reproducibility • Temperature-independent pulses in a large temperature range • Great…
File type: application/pdf
Referenced at:
Gear Type Flow Meter VC PULSE 2 KRACHT GmbH · Gewerbestr. 20 · 58791 Werdohl, Germany · Phone +49 23 92.935-0 · Fax +49 23 92.935 209 · Email info@kracht.eu · Web www.kracht.eu Gear Type Flow Meter VC PULSE Description C Product Characteristics • Selectable high measurement value resolution • Viscosity-independent measurements made in the frame of the stated ranges • Low pressure drop • Highly-dynamic measurements • High compression strength • Low noise emission • Highly-accurate measurements with outstanding reproducibility • Temperature-independent pulses in a large temperature range • Great…
File type: application/pdf
Referenced at:
EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.com1.66 E10414 Design G1/4 G1/2 G1/2 NPT1/2 G3/4 Dimensions Detection range [cm/s] water 1...100 / oil 3...200 Sensor length [mm] 25 31 48 40 48 Connection plug plug plug plug plug ID-No. P11164 P11165 P11166 P11167 P11169 Type STS 101 S STS 102 S STS 103 S STS 104 S STS 106 S Ex area of use Gas: Zone 0/1 / Dust: Zone 20 Certificate No. TÜV 98 ATEX 1298 X Ex marking Gas: II 1/2 G Ex ia IIC T6 Ga/Gb Dust: II 1 D Ex ia IIIC T100 °C Da Ambient temperature [°C] Gas: T6: – 20 Ta +40 and medium temperature T5: – 20 Ta +55 T4: – 20 Ta…
File type: application/pdf
Referenced at:
EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.com1.66 E10414 Design G1/4 G1/2 G1/2 NPT1/2 G3/4 Dimensions Detection range [cm/s] water 1...100 / oil 3...200 Sensor length [mm] 25 31 48 40 48 Connection plug plug plug plug plug ID-No. P11164 P11165 P11166 P11167 P11169 Type STS 101 S STS 102 S STS 103 S STS 104 S STS 106 S Ex area of use Gas: Zone 0/1 / Dust: Zone 20 Certificate No. TÜV 98 ATEX 1298 X Ex marking Gas: II 1/2 G Ex ia IIC T6 Ga/Gb Dust: II 1 D Ex ia IIIC T100 °C Da Ambient temperature [°C] Gas: T6: – 20 Ta +40 and medium temperature T5: – 20 Ta +55 T4: – 20 Ta…
File type: application/pdf
Referenced at:
EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.com1.66 E10414 Design G1/4 G1/2 G1/2 NPT1/2 G3/4 Dimensions Detection range [cm/s] water 1...100 / oil 3...200 Sensor length [mm] 25 31 48 40 48 Connection plug plug plug plug plug ID-No. P11164 P11165 P11166 P11167 P11169 Type STS 101 S STS 102 S STS 103 S STS 104 S STS 106 S Ex area of use Gas: Zone 0/1 / Dust: Zone 20 Certificate No. TÜV 98 ATEX 1298 X Ex marking Gas: II 1/2 G Ex ia IIC T6 Ga/Gb Dust: II 1 D Ex ia IIIC T100 °C Da Ambient temperature [°C] Gas: T6: – 20 Ta +40 and medium temperature T5: – 20 Ta +55 T4: – 20 Ta…
File type: application/pdf
Referenced at:
EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.com1.66 E10414 Design G1/4 G1/2 G1/2 NPT1/2 G3/4 Dimensions Detection range [cm/s] water 1...100 / oil 3...200 Sensor length [mm] 25 31 48 40 48 Connection plug plug plug plug plug ID-No. P11164 P11165 P11166 P11167 P11169 Type STS 101 S STS 102 S STS 103 S STS 104 S STS 106 S Ex area of use Gas: Zone 0/1 / Dust: Zone 20 Certificate No. TÜV 98 ATEX 1298 X Ex marking Gas: II 1/2 G Ex ia IIC T6 Ga/Gb Dust: II 1 D Ex ia IIIC T100 °C Da Ambient temperature [°C] Gas: T6: – 20 Ta +40 and medium temperature T5: – 20 Ta +55 T4: – 20 Ta…
File type: application/pdf
Referenced at:
GATEWAY to new technologies. Hydraulic / 250 bar Schwenkmotor PSM wear- resistant moving parts - long service life of the rotary actuator through extended-period nitriding - excellent sliding characteristics of the gears Spot the advantages…2 250 bar operating pressure - high performance in a very compact unit resulting in space and cost savings - increased safety margin - savings on accessories as only few applications will require pressure reducing valves to protect the SM4 adjustable drive shaft datum - if you manufacture the hub, it is not necessary to regard the exact position of the…