Special-Sensors for Automation ISO 9001 certified Infrared Detect ors ■ Measuring range 50...2000 °C ■ Analog and switching output ■ Fibre-optic up to 350 °C ■ For heavy industry - IP 68 EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.com6.02 EE60214 Function and application Where conventional sensors would fail due to too high temperature, infrared detectors working on a non-contact principle can be used. They respond to the radiated heat of the hot materials. Compact units with optics are used for distances of 2 to 8 m from the object. For distances of only a few cm,…
File type: application/pdf
Referenced at:
Special-Sensors for Automation ISO 9001 certified Infrared Detect ors ■ Measuring range 50...2000 °C ■ Analog and switching output ■ Fibre-optic up to 350 °C ■ For heavy industry - IP 68 EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.com6.02 EE60214 Function and application Where conventional sensors would fail due to too high temperature, infrared detectors working on a non-contact principle can be used. They respond to the radiated heat of the hot materials. Compact units with optics are used for distances of 2 to 8 m from the object. For distances of only a few cm,…
File type: application/pdf
Referenced at:
Special-Sensors for Automation ISO 9001 certified Infrared Detect ors ■ Measuring range 50...2000 °C ■ Analog and switching output ■ Fibre-optic up to 350 °C ■ For heavy industry - IP 68 EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.com6.02 EE60214 Function and application Where conventional sensors would fail due to too high temperature, infrared detectors working on a non-contact principle can be used. They respond to the radiated heat of the hot materials. Compact units with optics are used for distances of 2 to 8 m from the object. For distances of only a few cm,…
File type: application/pdf
Referenced at:
Special-Sensors for Automation ISO 9001 certified Infrared Detect ors Measuring-range 50...2000 °C Analog and switching output Fibre-optic up to 350 °C For heavy industry - IP 68 EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.com6.02 EE60410 Function and application Where conventional sensors would fail due to too high temperature, infrared detectors working on a non-contact principle can be used. They respond to the radiated heat of the hot materials. Compact units with optics are used for distances of 2 to 8 m from the object. For distances of only a few cm, heat-resistant…
File type: application/pdf
Referenced at:
The 2 color indicator type has been added for mounting onto the F-type miniature switch. 2 color switch mountable Compact/highly accurate actuator Actual size 10mm 18mm 43mm Ideal for high-accuracy positioning Highly accurate 0.005 mm sliding parallelism and 0.03 mm installation parallelism are ensured, making this actuator ideal for positioning. Ultimate pursuit of downsizing The cylinder, linear guide, and slide table have been integrated into a highly compact unit. 0.005mm 0.03mm Installation parallelism SeriesLCM 0.005mm 0.03mm 0.005mm 0.03mm Linear Slide Cylinder Table Guide Cylinder…
File type: application/pdf
Referenced at:
CATALOGO GENERALE LINEA ELICOIDALE GENERAL CATALOGUE HELICAL LINE REGGIANA RIDUTTORI S.r.l. Via Martiri di Marzabotto,7 42020 S. Polo d’Enza (RE) ITALY tel. +39.0522.259111 - fax +39.0522.874321 info@reggianariduttori.com www.reggianariduttori.com C400-1500-00 LI N EA E LI C O ID A LE - H EL IC A L LI N E INDICE GENERALITÀ DESIGNAZIONE, LEGENDA, RENDIMENTI FATTORE DI SERVIZIO POTENZA TERMICA IMPIANTI DI RAFFREDDAMENTO SELEZIONE DEL RIDUTTORE MODULO DI SELEZIONE DATI TECNICI Serie standard – Riduttori ad assi paralleli PA singolo stadio PB due stadi PC tre stadi PD quattro stadi Serie standard…
File type: application/pdf
Referenced at:
CATALOGO GENERALE LINEA ELICOIDALE GENERAL CATALOGUE HELICAL LINE REGGIANA RIDUTTORI S.r.l. Via Martiri di Marzabotto,7 42020 S. Polo d’Enza (RE) ITALY tel. +39.0522.259111 - fax +39.0522.874321 info@reggianariduttori.com www.reggianariduttori.com C400-1500-00 LI N EA E LI C O ID A LE - H EL IC A L LI N E INDICE GENERALITÀ DESIGNAZIONE, LEGENDA, RENDIMENTI FATTORE DI SERVIZIO POTENZA TERMICA IMPIANTI DI RAFFREDDAMENTO SELEZIONE DEL RIDUTTORE MODULO DI SELEZIONE DATI TECNICI Serie standard – Riduttori ad assi paralleli PA singolo stadio PB due stadi PC tre stadi PD quattro stadi Serie standard…
File type: application/pdf
Referenced at:
2020-2021 Lift General Catalogue 1 1 2A 2B 4 3 3 11 10A 10A 10B 10B 10C 10C 11 9 6 2A 2B 7 5 5 10B 2A 2B 3 11 13 21 8 Lift General Catalogue 2020-2021 Pizzato Elettrica devices have been used for many years in the lift sec- tor, for their proven reliability and quality to price ratio. Some of the products shown here have been the first choice of some of the most important multinational players; they are therefore used throughout the world. The range of position switches, traditionally used in the lift sector, is vast; for this reason, the following pages contain just some of the Pizzato…
File type: application/pdf
Referenced at:
FLB Series 104 Common specifications Descriptions Standard specifications Optional specifications Voltage Model no. FLB2 FLB3/4/5 3mA or less 6mA or less 1.5mA or less 3mA or less 1mA or less 2mA or less 100 VAC 200 VAC 24 VDC 12 VDC Le ak ag e cu rre nt Working fluid Working pressure differential range Withstanding pressure (water pressure) Fluid temperature Ambient temperature Heat proof class Atmosphere Valve structure Valve seat leakage Installation attitude Protective structure AC: -10 to 60 DC: -10 to 40 (no freezing) -10 to 90 (no freezing) AC: -20 to 60 DC: -20 to 40 -20 to 60 B H or…
File type: application/pdf
Referenced at:
FLB Series 104 Common specifications Descriptions Standard specifications Optional specifications Voltage Model no. FLB2 FLB3/4/5 3mA or less 6mA or less 1.5mA or less 3mA or less 1mA or less 2mA or less 100 VAC 200 VAC 24 VDC 12 VDC Le ak ag e cu rre nt Working fluid Working pressure differential range Withstanding pressure (water pressure) Fluid temperature Ambient temperature Heat proof class Atmosphere Valve structure Valve seat leakage Installation attitude Protective structure AC: -10 to 60 DC: -10 to 40 (no freezing) -10 to 90 (no freezing) AC: -20 to 60 DC: -20 to 40 -20 to 60 B H or…
File type: application/pdf
Referenced at: