High Pressure Gear Pumps KP 2 / KP 3 2 KRACHT GmbH · Gewerbestr. 20 · 58791 Werdohl, Germany · Phone +49 23 92.935-0 · Fax +49 23 92.935 209 · Email info@kracht.eu · Web www.kracht.eu High Pressure Gear Pumps KP2 /KP3 3KRACHT GmbH · Gewerbestr. 20 · 58791 Werdohl, Germany · Phone +49 23 92.935-0 · Fax +49 23 92.935 209 · Email info@kracht.eu · Web www.kracht.eu 1 Housing 2 Gear 3 Drive shaft end 4 Flange mounting cover 5 Gasket for the pressure fields for axial and play compensation 6 Sliding plates 7 Single rotary shaft lip 8 Plain bearings 9 Sealing of the housing Due to the construction…
File type: application/pdf
Referenced at:
High Pressure Gear Pumps KP 2 / KP 3 2 KRACHT GmbH · Gewerbestr. 20 · 58791 Werdohl, Germany · Phone +49 23 92.935-0 · Fax +49 23 92.935 209 · Email info@kracht.eu · Web www.kracht.eu High Pressure Gear Pumps KP2 /KP3 3KRACHT GmbH · Gewerbestr. 20 · 58791 Werdohl, Germany · Phone +49 23 92.935-0 · Fax +49 23 92.935 209 · Email info@kracht.eu · Web www.kracht.eu 1 Housing 2 Gear 3 Drive shaft end 4 Flange mounting cover 5 Gasket for the pressure fields for axial and play compensation 6 Sliding plates 7 Single rotary shaft lip 8 Plain bearings 9 Sealing of the housing Due to the construction…
File type: application/pdf
Referenced at:
Pressure Valves DV hydraulically pilot-operated Pressure Valves DV KRACHT GmbH · Gewerbestr. 20 · 58791 Werdohl, Germany · Phone +49 23 92.935-0 · Fax +49 23 92.935 209 · Email info@kracht.eu · Web www.kracht.eu2 The DV pressure valves are hydraulically pilot-control- led valves. They comprise a main valve and one or several pilot-controlled valves. The modular design permits using different pilot control valves which means a multitude of functions can be implemented. Along with pressure limiting and pressure control functions, this also includes special solutions such as pressure range…
File type: application/pdf
Referenced at:
Pressure Valves DV hydraulically pilot-operated Pressure Valves DV KRACHT GmbH · Gewerbestr. 20 · 58791 Werdohl, Germany · Phone +49 23 92.935-0 · Fax +49 23 92.935 209 · Email info@kracht.eu · Web www.kracht.eu2 The DV pressure valves are hydraulically pilot-control- led valves. They comprise a main valve and one or several pilot-controlled valves. The modular design permits using different pilot control valves which means a multitude of functions can be implemented. Along with pressure limiting and pressure control functions, this also includes special solutions such as pressure range…
File type: application/pdf
Referenced at:
F-5 (1-06) ROTARY VANE COMPRESSORS & VACUUM PUMPS 2 Here’s how our Rotary Vane performance compares with that of our other popular positive displacement vacuum pumps and compressors. Use these charts to see if a Rotary Vane pump is the right choice for your application. Why use a Rotary Vane pump? Rotary Vane vacuum pumps and compressors have certain significant advantages. In addition to providing smooth, pulse-free air flow without receiver tanks, they are compact (or equivalently offer high flow capacities for a given size), are simple and economical to install and operate, have low…
File type: application/pdf
Referenced at:
24 Continuous use possible up to 80 Stable inner seal performance achieved with nonrotating rod (Patent pending) Zero particle generation realized with optimum seal structure and improved surface roughness Valve dead space minimized Electropolished finish specifications Handle position and top indicator indicate whether the valve is open or closed. Panel installation possible Inner seal performance stabilized with spring High corrosion resistant Ni-Co alloy diaphragm JXR joint connection *1 Standard (male and female) and double barbed joints OGD10V OGD20V Working fluid Working pressure range…
File type: application/pdf
Referenced at:
24 Continuous use possible up to 80 Stable inner seal performance achieved with nonrotating rod (Patent pending) Zero particle generation realized with optimum seal structure and improved surface roughness Valve dead space minimized Electropolished finish specifications Handle position and top indicator indicate whether the valve is open or closed. Panel installation possible Inner seal performance stabilized with spring High corrosion resistant Ni-Co alloy diaphragm JXR joint connection *1 Standard (male and female) and double barbed joints OGD10V OGD20V Working fluid Working pressure range…
File type: application/pdf
Referenced at:
M icron TRUE Planetary ™ Gearheads www.thomsonlinear.com TRUE Planetary™ Gearheads October 2012 EN http://www.thomsonlinear.com/website/com/eng/products/gearheads.php Thomson – the Choice for Optimized Motion Solutions Often the ideal design solution is not about finding the fastest, sturdiest, most accurate or even the least expensive option. Rather, the ideal solution is the optimal balance of performance, life and cost. The Best Positioned Supplier of Mechanical Motion Technology Thomson has several advantages that makes us the supplier of choice for motion control technology. • Thomson own…
File type: application/pdf
Referenced at:
M icron TRUE Planetary ™ Gearheads www.thomsonlinear.com TRUE Planetary™ Gearheads October 2012 EN http://www.thomsonlinear.com/website/com/eng/products/gearheads.php Thomson – the Choice for Optimized Motion Solutions Often the ideal design solution is not about finding the fastest, sturdiest, most accurate or even the least expensive option. Rather, the ideal solution is the optimal balance of performance, life and cost. The Best Positioned Supplier of Mechanical Motion Technology Thomson has several advantages that makes us the supplier of choice for motion control technology. • Thomson own…
File type: application/pdf
Referenced at:
Transfer Gear Pumps KF 1/4 -- KF 1/24 coated Gear Pumps KF 1/4 -- KF 1/24 coated KRACHT GmbH · Gewerbestr. 20 · 58791 Werdohl, Germany · Phone +49(0)23 92 /935-0 · Fax +49(0)23 92 /935 209 · www.kracht-hydraulik.de · info@kracht-hydraulik.de 3 Content Description, Construction . . . . . . . . . . . . . . . . . . . . . 4 Characteristics and Materials . . . . . . . . . . . . . . . . . . . 5 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Discharge Flow, Power Input . . . . . . . . . . . . . . . . . . . 6 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . .…
File type: application/pdf
Referenced at: