266 Individual specifications Model no. Descriptions Port size Orifice (mm) Min. working pressure diff. (MPa) Rated voltage Max. working pressure diff. (MPa) Apparent power (VA) Power consumption (W) Air AC DC AC DC AC DC AC 50Hz 60Hz50Hz60Hz Water, kerosene Oil (20 mm2/s) Steam Holding Starting AC 50/60Hz DC Mass (kg) APK11-8A APK11-10A APK11-15A APK11-20A APK11-25A Rc1/4 Rc3/8 Rc1/2 Rc3/4 Rc1 12 12 16 23 28 0 1 0.7 0.6 1 0.7 0.6 24 32 19 26 61 123 54 106 10/8 13/11 14 20 0.7 1 0.6 0.5 100 VAC 50/60Hz 110 VAC 60Hz 200 VAC 50/60Hz 220 VAC 60Hz 12 VDC 24 VDC 48 VDC 100 VDC 0.7 0.7 1.0 1.3 1.7…
File type: application/pdf
Referenced at:
266 Individual specifications Model no. Descriptions Port size Orifice (mm) Min. working pressure diff. (MPa) Rated voltage Max. working pressure diff. (MPa) Apparent power (VA) Power consumption (W) Air AC DC AC DC AC DC AC 50Hz 60Hz50Hz60Hz Water, kerosene Oil (20 mm2/s) Steam Holding Starting AC 50/60Hz DC Mass (kg) APK11-8A APK11-10A APK11-15A APK11-20A APK11-25A Rc1/4 Rc3/8 Rc1/2 Rc3/4 Rc1 12 12 16 23 28 0 1 0.7 0.6 1 0.7 0.6 24 32 19 26 61 123 54 106 10/8 13/11 14 20 0.7 1 0.6 0.5 100 VAC 50/60Hz 110 VAC 60Hz 200 VAC 50/60Hz 220 VAC 60Hz 12 VDC 24 VDC 48 VDC 100 VDC 0.7 0.7 1.0 1.3 1.7…
File type: application/pdf
Referenced at:
266 Individual specifications Model no. Descriptions Port size Orifice (mm) Min. working pressure diff. (MPa) Rated voltage Max. working pressure diff. (MPa) Apparent power (VA) Power consumption (W) Air AC DC AC DC AC DC AC 50Hz 60Hz50Hz60Hz Water, kerosene Oil (20 mm2/s) Steam Holding Starting AC 50/60Hz DC Mass (kg) APK11-8A APK11-10A APK11-15A APK11-20A APK11-25A Rc1/4 Rc3/8 Rc1/2 Rc3/4 Rc1 12 12 16 23 28 0 1 0.7 0.6 1 0.7 0.6 24 32 19 26 61 123 54 106 10/8 13/11 14 20 0.7 1 0.6 0.5 100 VAC 50/60Hz 110 VAC 60Hz 200 VAC 50/60Hz 220 VAC 60Hz 12 VDC 24 VDC 48 VDC 100 VDC 0.7 0.7 1.0 1.3 1.7…
File type: application/pdf
Referenced at:
13 110/217 ED 1/24 — The FV6 pumps are fixed displacement vane pumps, with several nominal displacement each. Single, double and triple pumps are available. — The pumping group is composed of a cartridge element that contains rotor, vanes, cam ring and support plates. Cartridges are easily removable without disconnecting the pump from the hydraulic circuit, thus simplify the maintenance operations. — The special elliptical profile of the cam ring, with double suction and delivery chambers one against the other, eliminates the radial thrusts on the rotor, reducing wear of the pump. The use of a…
File type: application/pdf
Referenced at:
13 110/217 ED 1/24 — The FV6 pumps are fixed displacement vane pumps, with several nominal displacement each. Single, double and triple pumps are available. — The pumping group is composed of a cartridge element that contains rotor, vanes, cam ring and support plates. Cartridges are easily removable without disconnecting the pump from the hydraulic circuit, thus simplify the maintenance operations. — The special elliptical profile of the cam ring, with double suction and delivery chambers one against the other, eliminates the radial thrusts on the rotor, reducing wear of the pump. The use of a…
File type: application/pdf
Referenced at:
14-07-2009 Symbols of Vivoil Oleodinamica Vivolo products XV-0P XV-0U XV-1P Left Rotation Right Rotation XV-1U Left Rotation Right Rotation XV-2P XV-2U XV-3P XV-3U XV-0R XV-0M XV-1R External drainage Internal drainage XV-1M External drainage Internal drainage XV-2R XV-2M XV-3R XV-3M XV-0T XV-1T XV-2T XV-3T Primary element of multiple pump XV-0I XV-1I XV-2I XV-3I Intermediate element of multiple pump XV-0F XV-1F XV-2F XV-3F Final element of multiple pump KV -DF KV -DFV KV -DF+M Unidirectional Pump Unidirectional Motor Reversible Pump Reversible Motor Left Rotation Right Rotation The…
File type: application/pdf
Referenced at:
14-07-2009 Symbols of Vivoil Oleodinamica Vivolo products XV-0P XV-0U XV-1P Left Rotation Right Rotation XV-1U Left Rotation Right Rotation XV-2P XV-2U XV-3P XV-3U XV-0R XV-0M XV-1R External drainage Internal drainage XV-1M External drainage Internal drainage XV-2R XV-2M XV-3R XV-3M XV-0T XV-1T XV-2T XV-3T Primary element of multiple pump XV-0I XV-1I XV-2I XV-3I Intermediate element of multiple pump XV-0F XV-1F XV-2F XV-3F Final element of multiple pump KV -DF KV -DFV KV -DF+M Unidirectional Pump Unidirectional Motor Reversible Pump Reversible Motor Left Rotation Right Rotation The…
File type: application/pdf
Referenced at:
REGGIANA RIDUTTORI S.r.l. Via Martiri di Marzabotto,7 42020 S. Polo d’Enza (RE) ITALY tel. +39.0522.259111 - fax +39.0522.874321 info@reggianariduttori.com www.reggianariduttori.com C200-1800-00 CATALOGO GENERALE RIDUTTORI EPICICLOIDALI GENERAL CATALOGUE PLANETARY REDUCTION GEARS GESAMTKATALOG PLANETENGETRIEBE CATALOGUE GÉNÉRAL REDUCTEURS EPICYCLOIDAUX CATÁLOGO GENERAL REDUCTORES EPICICLOIDALES CATÁLOGO GERAL REDUTORES EPICICLOIDAIS RR65 ÷ RR1700 INDICE INDEX INHALTSVERZEICHNIS A Informazioni generali General information Allgemeine Informationen 1 SIMBOLOGIA 1 SYMBOLS 1 VERWENDETE SYMBOLE A-2…
File type: application/pdf
Referenced at:
REGGIANA RIDUTTORI S.r.l. Via Martiri di Marzabotto,7 42020 S. Polo d’Enza (RE) ITALY tel. +39.0522.259111 - fax +39.0522.874321 info@reggianariduttori.com www.reggianariduttori.com C200-1800-00 CATALOGO GENERALE RIDUTTORI EPICICLOIDALI GENERAL CATALOGUE PLANETARY REDUCTION GEARS GESAMTKATALOG PLANETENGETRIEBE CATALOGUE GÉNÉRAL REDUCTEURS EPICYCLOIDAUX CATÁLOGO GENERAL REDUCTORES EPICICLOIDALES CATÁLOGO GERAL REDUTORES EPICICLOIDAIS RR65 ÷ RR1700 INDICE INDEX INHALTSVERZEICHNIS A Informazioni generali General information Allgemeine Informationen 1 SIMBOLOGIA 1 SYMBOLS 1 VERWENDETE SYMBOLE A-2…
File type: application/pdf
Referenced at:
Rodless cylinder SRL3 Series New Products Features Specifications (double acting standard type) Note 1: Piston speed used with common port piping differs with the stroke. Contact CKD for details. Descriptions SRL3 Bore size mm ø25 ø32 ø40 ø50 ø63 Actuation Double acting Working fluid Compressed air Max. working pressure MPa 0.7 Min. working pressure MPa 0.1 0.05 Withstanding pressure MPa 1.05 Ambient temperature °C 5 to 60 Port size Rc1/8 Rc1/4 Rc3/8 Stroke tolerance mm (to 1000), (to 3000), (to 5000) Working piston speed mm/s 50 to 2000 (with standard port piping) (Note 1) Cushion Air cushion…
File type: application/pdf
Referenced at: