Special-Sensors for Automation Flow Sensors EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.com1.02 E10414 Flow Sensors Contents Technique and application for flow sensors Technique and application for flow sensors, amplifiers and compact models . . . . . . . . 1.03 - 1.07 Terminology / Setting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.08 - 1.09 Technique and application flow sensors inline-digital display . . . . . . . . . . . . . . . . . . . . . . . . . . 1.10 Ex area certification, valid standards . . . . . . . . .…
File type: application/pdf
Referenced at:
Special-Sensors for Automation Flow Sensors EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.com1.02 E10414 Flow Sensors Contents Technique and application for flow sensors Technique and application for flow sensors, amplifiers and compact models . . . . . . . . 1.03 - 1.07 Terminology / Setting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.08 - 1.09 Technique and application flow sensors inline-digital display . . . . . . . . . . . . . . . . . . . . . . . . . . 1.10 Ex area certification, valid standards . . . . . . . . .…
File type: application/pdf
Referenced at:
Special-Sensors for Automation Flow Sensors EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.com1.02 E10414 Flow Sensors Contents Technique and application for flow sensors Technique and application for flow sensors, amplifiers and compact models . . . . . . . . 1.03 - 1.07 Terminology / Setting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.08 - 1.09 Technique and application flow sensors inline-digital display . . . . . . . . . . . . . . . . . . . . . . . . . . 1.10 Ex area certification, valid standards . . . . . . . . .…
File type: application/pdf
Referenced at:
Special-Sensors for Automation Flow Sensors EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.com1.02 E10414 Flow Sensors Contents Technique and application for flow sensors Technique and application for flow sensors, amplifiers and compact models . . . . . . . . 1.03 - 1.07 Terminology / Setting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.08 - 1.09 Technique and application flow sensors inline-digital display . . . . . . . . . . . . . . . . . . . . . . . . . . 1.10 Ex area certification, valid standards . . . . . . . . .…
File type: application/pdf
Referenced at:
GEM 20 TAPmaster -13830 min 420 min-1 M 20 S D40 ● Gewindeschneideinheit mit mechanischem Vorschub ▲ Tapping unit with integrated leadscrew ■ Unité de taraudage avec avance mécanique ● Technische Daten Gesamthub 100 mm Gewindeschneidleistung M 20 / 600 N/mm2 Gewindesteigung min. 0,4 – max. 2,5 Übertragbares Drehmoment max. 80 Nm Drehzahlbereich bei 50 Hz 420 –1440 min-1 Induktiver Endschalter 20–250 V AC/DC Bremsmotor bei 50 Hz 1,5 kW / 1435 min-1 Gewicht / Farbe 54 kg / RAL 5012 ▲ Technical Data Total stroke 100 mm Tapping capacity M 20 / 600 N/mm2 Thread pitch min. 0.4 – max. 2.5…
File type: application/pdf
Referenced at:
VOLUMEC Valve Position Indicator 5 VOLUMEC Valve Position Indicator 5 Description Modular design VOLUMEC Indicator AVC .. A Optically AVC .. B Open /Close switches AVC .. C/CL Potentiometer AVC .. D/DL Potentiometer + o/c switches The VOLUMEC 5 valve position indicator consists of one volume counter and one indicator device. Mounted on a connecting plate, the VOLUMEC 5 carries out the functions of measuring and counting the adjustment track of hydraulically operated ship armatures. The measurement unit is seawater-resistant and suitable for being mounted on deck. The volumetrically ascertained…
File type: application/pdf
Referenced at:
VOLUMEC Valve Position Indicator 5 VOLUMEC Valve Position Indicator 5 Description Modular design VOLUMEC Indicator AVC .. A Optically AVC .. B Open /Close switches AVC .. C/CL Potentiometer AVC .. D/DL Potentiometer + o/c switches The VOLUMEC 5 valve position indicator consists of one volume counter and one indicator device. Mounted on a connecting plate, the VOLUMEC 5 carries out the functions of measuring and counting the adjustment track of hydraulically operated ship armatures. The measurement unit is seawater-resistant and suitable for being mounted on deck. The volumetrically ascertained…
File type: application/pdf
Referenced at:
VOLUMEC Valve Position Indicator 5 VOLUMEC Valve Position Indicator 5 Description Modular design VOLUMEC Indicator AVC .. A Optically AVC .. B Open /Close switches AVC .. C/CL Potentiometer AVC .. D/DL Potentiometer + o/c switches The VOLUMEC 5 valve position indicator consists of one volume counter and one indicator device. Mounted on a connecting plate, the VOLUMEC 5 carries out the functions of measuring and counting the adjustment track of hydraulically operated ship armatures. The measurement unit is seawater-resistant and suitable for being mounted on deck. The volumetrically ascertained…
File type: application/pdf
Referenced at:
Special-Sensors for Automation ISO 9001 certified Ultraso nic Sen sors ■ Level control ■ Distance measurement ■ Monitoring of all materials ■ Waterproof ■ Teach-in function EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.com7.02 EU70213 Basics Ultrasonic sensors are transmitting and receiving ultrasonic signals. These signals have a frequency range from 65 kHz up to 300 kHz. Ultrasonic sen- sors can be used for several different applications, for example: diameter detection looptension height detection level measuring counting Application notes Non-contact detection of: •…
File type: application/pdf
Referenced at:
Special-Sensors for Automation ISO 9001 certified Ultraso nic Sen sors ■ Level control ■ Distance measurement ■ Monitoring of all materials ■ Waterproof ■ Teach-in function EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.com7.02 EU70213 Basics Ultrasonic sensors are transmitting and receiving ultrasonic signals. These signals have a frequency range from 65 kHz up to 300 kHz. Ultrasonic sen- sors can be used for several different applications, for example: diameter detection looptension height detection level measuring counting Application notes Non-contact detection of: •…
File type: application/pdf
Referenced at: