Special-Sensors for Automation System 3000 ■ for jaw crusher ■ for conveyer belt monitoring ■ for waste separation ISO 9001 certified Metal D etectors MU 3300 MDS...S MU 3300 3 m MDS ...S MDV... 3 m MA 125 Typ A Typ B MA 125 Typ ATyp B 60 EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.com8.02 EE80315 The metal detector System 3000 is designed to detect medi- um size and larger pieces of metal. The system has a very effective means of adjusting sensitivity. When used with the MU 3300 amplifier, it will respond at the highest level of sen- sitivity to medium size parts like…
File type: application/pdf
Referenced at:
Special-Sensors for Automation System 3000 ■ for jaw crusher ■ for conveyer belt monitoring ■ for waste separation ISO 9001 certified Metal D etectors MU 3300 MDS...S MU 3300 3 m MDS ...S MDV... 3 m MA 125 Typ A Typ B MA 125 Typ ATyp B 60 EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.com8.02 EE80315 The metal detector System 3000 is designed to detect medi- um size and larger pieces of metal. The system has a very effective means of adjusting sensitivity. When used with the MU 3300 amplifier, it will respond at the highest level of sen- sitivity to medium size parts like…
File type: application/pdf
Referenced at:
Partner for Performance www.ringfeder.com 08.2019 Assembly, Disassembly, Maintenance Friction Springs RINGFEDER® EN 08.2019EN Assembly, Disassembly, Maintenance Lubrication An essential factor for long service life is a sufficient lubrication of the springs. All friction springs are supplied in greased condition - ready to be installed. Loose rings are oiled for the protection against corrosion. They must be cleaned and then greased with RINGFEDER® special grease on all surfaces prior to installing. It has to be ensured for all springs that an excess of grease may escape (e.g. through a groove…
File type: application/pdf
Referenced at:
Partner for Performance www.ringfeder.com 08.2019 Assembly, Disassembly, Maintenance Friction Springs RINGFEDER® EN 08.2019EN Assembly, Disassembly, Maintenance Lubrication An essential factor for long service life is a sufficient lubrication of the springs. All friction springs are supplied in greased condition - ready to be installed. Loose rings are oiled for the protection against corrosion. They must be cleaned and then greased with RINGFEDER® special grease on all surfaces prior to installing. It has to be ensured for all springs that an excess of grease may escape (e.g. through a groove…
File type: application/pdf
Referenced at:
Optimal transfer of power A compact fixed-displacement axial piston motor. Uni-directional or Bi-directional configuration Low-speed operation—down to 1-2 rpm Speed sensor output allows for precise RPM control Constant speed over a wide temperature range AG M 6 M ot or SPECIFICATIONS Geometric Displacement 2.0 in3 [32 cc/rev] Pressure Rating Continuous 950 psi [65 bar] Intermittent 1450 psi [100 bar] Peak 1800 psi [124 bar] Output Speed Continuous 120 rpm Peak 360 rpm Torque Continuous 15 ft-lb Peak 26 ft-lb Case Pressure Continuous 200 psi [14 bar] Peak 300 psi [21 bar] Weight 4.5 lbs [2 kg]…
File type: application/pdf
Referenced at:
Optimal transfer of power A compact fixed-displacement axial piston motor. Uni-directional or Bi-directional configuration Low-speed operation—down to 1-2 rpm Speed sensor output allows for precise RPM control Constant speed over a wide temperature range AG M 6 M ot or SPECIFICATIONS Geometric Displacement 2.0 in3 [32 cc/rev] Pressure Rating Continuous 950 psi [65 bar] Intermittent 1450 psi [100 bar] Peak 1800 psi [124 bar] Output Speed Continuous 120 rpm Peak 360 rpm Torque Continuous 15 ft-lb Peak 26 ft-lb Case Pressure Continuous 200 psi [14 bar] Peak 300 psi [21 bar] Weight 4.5 lbs [2 kg]…
File type: application/pdf
Referenced at:
Chemical liquid manual valve/toggle valve MMD Overview This chemical liquid manual valve for semiconductor manufacturing equipment is available in 1/8 inch to 1 inch port sizes and different operations. Features The spring seal provides stable sealing. (MMD**2, GMMD**2, TMD series) Assorted fitting variations The easy-to-read indicator enables open/close status to be checked visually. No harmful polyvinyl chlorides No harmful polyvinyl chlorides generating toxic chlorine-based gases are used in actuator material. (MMD*02, GMMD*02 Series) Precautions Intro 7 2 port valve MMD*02 PFA body 76…
File type: application/pdf
Referenced at:
Chemical liquid manual valve/toggle valve MMD Overview This chemical liquid manual valve for semiconductor manufacturing equipment is available in 1/8 inch to 1 inch port sizes and different operations. Features The spring seal provides stable sealing. (MMD**2, GMMD**2, TMD series) Assorted fitting variations The easy-to-read indicator enables open/close status to be checked visually. No harmful polyvinyl chlorides No harmful polyvinyl chlorides generating toxic chlorine-based gases are used in actuator material. (MMD*02, GMMD*02 Series) Precautions Intro 7 2 port valve MMD*02 PFA body 76…
File type: application/pdf
Referenced at:
Chemical liquid manual valve/toggle valve MMD Overview This chemical liquid manual valve for semiconductor manufacturing equipment is available in 1/8 inch to 1 inch port sizes and different operations. Features The spring seal provides stable sealing. (MMD**2, GMMD**2, TMD series) Assorted fitting variations The easy-to-read indicator enables open/close status to be checked visually. No harmful polyvinyl chlorides No harmful polyvinyl chlorides generating toxic chlorine-based gases are used in actuator material. (MMD*02, GMMD*02 Series) Precautions Intro 7 2 port valve MMD*02 PFA body 76…
File type: application/pdf
Referenced at:
3 3D d ra w in gs a va ila bl e at w w w .v uo to te cn ic a. ne t 3.07 Conversion ratio: inch = ; pounds = = 25.4 453.6 0.4536 mm g Kg GAS-NPT thread adapters available at page 1.117 Adjustment screw Vacuum connection NBR rubber protection Adjustment screw Vacuum connection NBR rubber protection These vacuum switches feature reduced overall dimensions and give an electric signal when a certain adjustable vacuum level is reached. The pressure differential existing between the set maximum value and the value of reset of the rest signal is 50 ÷60 mbar and it is not adjustable. They are…
File type: application/pdf
Referenced at: