ADATUM FITNESS HEALTH IS A JOURNEY, NOT A DESTINATION A Brand from AUTOL Group We provide you: • Systematic Lubrication Solutions • Automatic Lubrication Pumps • Dividers • Manual Greasing Devices • Lubrication Accessories Contact Add.: Kleiner Johannes 21, D-91257, Pegnitz, Germany Tel.: +49 9241 80 89 87 00 Email: info@lubmann-gmbh.de Website: www.lubmann-gmbh.de ABOUT US Lubmann GmbH was founded by the Autol Group in Dusseldorf in 2015. The AUTOL Group is one of the world’s leading manufacturers of centralized lubrication systems. The automatic central lubrication systems of Lubmann GmbH…
File type: application/pdf
Referenced at:
ADATUM FITNESS HEALTH IS A JOURNEY, NOT A DESTINATION A Brand from AUTOL Group We provide you: • Systematic Lubrication Solutions • Automatic Lubrication Pumps • Dividers • Manual Greasing Devices • Lubrication Accessories Contact Add.: Kleiner Johannes 21, D-91257, Pegnitz, Germany Tel.: +49 9241 80 89 87 00 Email: info@lubmann-gmbh.de Website: www.lubmann-gmbh.de ABOUT US Lubmann GmbH was founded by the Autol Group in Dusseldorf in 2015. The AUTOL Group is one of the world’s leading manufacturers of centralized lubrication systems. The automatic central lubrication systems of Lubmann GmbH…
File type: application/pdf
Referenced at:
48 www.sensopart.com - VISOR® Object Sensor from Page 62 V10-OB-S1-W12 • Standard version configurable for 8 inspection tasks, up to 32 evaluations can be used for each inspection task > > Page 70 V20-OB-A2-W12 • Advanced version configurable for 255 inspection tasks as required, with 255 evaluations per inspection task as desired • Megapixel resolution > > Page 64 VISOR® Solar Sensor from Page 98 V10-SO-S1-W6 • Standard version for detecting position and breakouts of wafers and cells • Easy operation without previous knowledge of image processing > > Page 104 V10-SO-A1-W6 • Advanced version…
File type: application/pdf
Referenced at:
48 www.sensopart.com - VISOR® Object Sensor from Page 62 V10-OB-S1-W12 • Standard version configurable for 8 inspection tasks, up to 32 evaluations can be used for each inspection task > > Page 70 V20-OB-A2-W12 • Advanced version configurable for 255 inspection tasks as required, with 255 evaluations per inspection task as desired • Megapixel resolution > > Page 64 VISOR® Solar Sensor from Page 98 V10-SO-S1-W6 • Standard version for detecting position and breakouts of wafers and cells • Easy operation without previous knowledge of image processing > > Page 104 V10-SO-A1-W6 • Advanced version…
File type: application/pdf
Referenced at:
Transfer Gear Pumps KF 4/125...KF 6/730 with magnetic coupling KRACHT GmbH · Gewerbestr. 20 · 58791 Werdohl, Germany · fon +49(0)23 92/935-0 · fax +49(0)23 92/935 209 · mail info@kracht.eu · web www.kracht.eu2 Construction Transfer Gear Pumps KF 4/125...KF 6/730 with magnetic coupling 1 Housing 2 Flange mounting cover 3 Drive shaft 4 Gearing 5 End cover 6 Plain bearing bush 7 Outboard bearing 8 Adapter flange 9 Inner rotor 10 Outer rotor 11 Split case 12 Flange hub 13 Bell housing 14 Driven motor 15 O-Ring Function Conventional sealing gaskets are pushed to their limits with different…
File type: application/pdf
Referenced at:
Transfer Gear Pumps KF 4/125...KF 6/730 with magnetic coupling KRACHT GmbH · Gewerbestr. 20 · 58791 Werdohl, Germany · fon +49(0)23 92/935-0 · fax +49(0)23 92/935 209 · mail info@kracht.eu · web www.kracht.eu2 Construction Transfer Gear Pumps KF 4/125...KF 6/730 with magnetic coupling 1 Housing 2 Flange mounting cover 3 Drive shaft 4 Gearing 5 End cover 6 Plain bearing bush 7 Outboard bearing 8 Adapter flange 9 Inner rotor 10 Outer rotor 11 Split case 12 Flange hub 13 Bell housing 14 Driven motor 15 O-Ring Function Conventional sealing gaskets are pushed to their limits with different…
File type: application/pdf
Referenced at:
Bansbach easylift GmbH Barbarossastraße 8 D-73547 Lorch Tel. +49 (0) 7172/9107-0 Fax +49 (0) 7172/9107-44 info@bansbach.de www.bansbach.de Technische Änderungen und Druckfehler vorbehalten. The flyer is subject to technical alterations and printing mistakes. 04/2012 The new Click System - integrated in your gas spring With the new Click System, it is possible to lock the gas spring in its inserted final position. This adjustment can be released without any further release systems. The piston rod has just to be pushed in slightly in order to move out then the complete stroke. This development…
File type: application/pdf
Referenced at:
49 DEUBLIN 10 G ³/₈ 1109-021-188 M 16 x 1,5 LH 53 129 31 11 9 24 - 13 22 5 - G ¹/₄ 0,6 8 G ¹/₄ 1109-024-212 M 16 x 1,5 LH 53 129 31 11 5 24 - 13 22 5 - G ¹/₄ 0,6 10 G ³/₈ 1109-020-188 M 16 x 1,5 LH 53 135 31 11 9 24 105 - - 5 - G ¹/₄ 0,6 8 G ¹/₄ 1109-023-212 M 16 x 1,5 LH 53 135 31 11 5 24 105 - - 5 - G ¹/₄ 0,6 DN B A C D E F G H I J K L M N P ø ø ø PT 3 x 120° 17,994 17,989 17,994 17,989 17,994 17,989 17,994 17,989 1,520 PSI 105 bar 1,020 PSI 70 bar 1,020 PSI 70 bar 20,000 RPM 20.000 min-1 15,000 RPM 15.000 min-1 10,000 RPM 10.000 min-1 4.1 GPM 15 l/min 13.8 GPM 50 l/min 13.8 GPM 50 l/min kg…
File type: application/pdf
Referenced at:
STACKABLE DIRECTIONAL CONTROL VALVES CONTENTS: SVM06... .................................................................... SVK06... .................................................................. SVM04... ................................................................. Page 1/35...28/39 29/39...30/39 31/39...39/39 1/39 SUBPLATE Cover P T GENERAL DESCRIPTION SVM06...-... 4/3- and 4/2- way directional control valves with solenoid operation Thread connection of working ports “A” and “B” except for RH06...1-.../...GFS modification Up to 8 sections for horizontal stacking & up to 4 sections…
File type: application/pdf
Referenced at:
STACKABLE DIRECTIONAL CONTROL VALVES CONTENTS: SVM06... .................................................................... SVK06... .................................................................. SVM04... ................................................................. Page 1/35...28/39 29/39...30/39 31/39...39/39 1/39 SUBPLATE Cover P T GENERAL DESCRIPTION SVM06...-... 4/3- and 4/2- way directional control valves with solenoid operation Thread connection of working ports “A” and “B” except for RH06...1-.../...GFS modification Up to 8 sections for horizontal stacking & up to 4 sections…
File type: application/pdf
Referenced at: