20 -101.3 to 0kPa Red 0 to 1MPa Blue 0 to 100kPa Green Carrier diffusion type semiconductor strain gauge Air / dry compressed air 0.3MPa ± 1%F.S. 3%F.S. or less ± 3%F.S. DC10 to 30V 5 to 50mA 4V or less 1mA or less When power turns ON, yellow LED lights Standard 3m (oil resistant vinyl cabtire code 2-conductor 0.15mm2) 0 to 50 °C (to be unfrozen.) Equivalent to IEC standards IP65 R1/8, 6 dia. plug and 6 dia. push in joint 0.6MPa 1.5MPa Pressure range Name plate color Note 2 Pressure sensitive element Applicable fluid Withstanding pressure Repeatability Hysteresis Temperature characteristics…
File type: application/pdf
Referenced at:
SOFFIANTI A CANALE BLOWERS POMPE A PALETTE A SECCO DRY ROTARY VANE POMPE A PALETTE LUBRIFICATE OIL ROTARY VANE SOFFIATORI A LOBI COMPRESSORS DIFFUSORI DIFFUSERS VENTILATORI INDUSTRIALI INDUSTRIAL FANS POMPE A UNCINO CLAW PUMPS TURBO SOFFIANTI TURBO BLOWERS ITALIAN VACUUM COMPRESSORS POMPE AD ANELLO LIQUIDO LIQUID RING VACUUM PUMPS 2 Principio di funzionamento Le pompe della serie ALM/ALL appartengono alla famiglia delle pompe per vuoto ad anello liquido. Sono costituite da un corpo cilindrico nel quale ruota in posizione eccentrica una girante a pale radiali. Il liquido di servizio, posto in…
File type: application/pdf
Referenced at:
SOFFIANTI A CANALE BLOWERS POMPE A PALETTE A SECCO DRY ROTARY VANE POMPE A PALETTE LUBRIFICATE OIL ROTARY VANE SOFFIATORI A LOBI COMPRESSORS DIFFUSORI DIFFUSERS VENTILATORI INDUSTRIALI INDUSTRIAL FANS POMPE A UNCINO CLAW PUMPS TURBO SOFFIANTI TURBO BLOWERS ITALIAN VACUUM COMPRESSORS POMPE AD ANELLO LIQUIDO LIQUID RING VACUUM PUMPS 2 Principio di funzionamento Le pompe della serie ALM/ALL appartengono alla famiglia delle pompe per vuoto ad anello liquido. Sono costituite da un corpo cilindrico nel quale ruota in posizione eccentrica una girante a pale radiali. Il liquido di servizio, posto in…
File type: application/pdf
Referenced at:
Servo & Step Motors and Drives Servo & Step Motors and Drives www.DanaherMotion.comwww.DanaherMotion.com 2 Danaher Motion’s wide range of motion control systems and components offer customers an unprecedented choice in selecting the right solution to match their particular application requirements. Our product innovations have been improving the efficiency and productivity of complex manufacturing operations for over 80 years through trusted brand names such as Dover, Kollmorgen, Pacific Scientific, Portescap and Thomson in industries as diverse as semiconductor, aerospace and defense, mobile-…
File type: application/pdf
Referenced at:
Kinetics Base jaw for fitting the workpiece specific gripper fingers Finger body high-tensile aluminum body with lightest possible because of hard anodizing AF06-30,40 Gripper Link lever type www.jrtfa.com Drive double acting pneumatic cylinder Angular type by link lever driving unit Suitable to grip for cylindrical & global workpiece Magnetic sensor is available for open-close sensing toggle system for centric accurate gripping 170 Character AF06 Gripper Body Wrench Bolt Piston Packing Cyl inder O-Ring Cyl inder Body Damper Ring Master Jaw Piston Snap Ring Hinge Pin Plunger Magnet Bracket…
File type: application/pdf
Referenced at:
Kinetics Base jaw for fitting the workpiece specific gripper fingers Finger body high-tensile aluminum body with lightest possible because of hard anodizing AF06-30,40 Gripper Link lever type www.jrtfa.com Drive double acting pneumatic cylinder Angular type by link lever driving unit Suitable to grip for cylindrical & global workpiece Magnetic sensor is available for open-close sensing toggle system for centric accurate gripping 170 Character AF06 Gripper Body Wrench Bolt Piston Packing Cyl inder O-Ring Cyl inder Body Damper Ring Master Jaw Piston Snap Ring Hinge Pin Plunger Magnet Bracket…
File type: application/pdf
Referenced at:
Kinetics Base jaw for fitting the workpiece specific gripper fingers Finger body high-tensile aluminum body with lightest possible because of hard anodizing AF06-30,40 Gripper Link lever type www.jrtfa.com Drive double acting pneumatic cylinder Angular type by link lever driving unit Suitable to grip for cylindrical & global workpiece Magnetic sensor is available for open-close sensing toggle system for centric accurate gripping 170 Character AF06 Gripper Body Wrench Bolt Piston Packing Cyl inder O-Ring Cyl inder Body Damper Ring Master Jaw Piston Snap Ring Hinge Pin Plunger Magnet Bracket…
File type: application/pdf
Referenced at:
ELECTRONIC PRESSURE REGULAT O R P N E U M ATIC DIVISION EPR 50 MATRIX m e c h a t r o n i c s epr50 10-05-2006 10:42 Pagina 1 EPR 50 - ELECTRONIC PRESSURE REGULATOR The EPR 50 is a closed loop, panel mounting, electronic pressure regulator able to convert a variable analog or digital input signal (current, voltage, RS-232) into a proportional pneumatic output and maintain with precision a required dow- nstream pressure. Equipped with an 8 bit microcontroller, it can process signals and commands, carry out complex fun- ctions and easily interface with other control/monitor systems via serial…
File type: application/pdf
Referenced at:
DuroTec® Gear Pumps DT DuroTec® Gear Pumps DT for abrasive and poor lubricating fluids. In the year 1990, KRACHT initiated the development of Gear Pumps for abrasive and poor lubricating fluids. Since then, this development has been subsequently improved. The limit of applications of Gear Pumps has been reached when the transfer medium does not have the required lubricity for a proper function of the pump and a high working pressure is needed at the same time. Such problematic fluids are for example silicates (sodium silicate), isocyanates and polyols with hard fillers as can be found in the…
File type: application/pdf
Referenced at:
DuroTec® Gear Pumps DT DuroTec® Gear Pumps DT for abrasive and poor lubricating fluids. In the year 1990, KRACHT initiated the development of Gear Pumps for abrasive and poor lubricating fluids. Since then, this development has been subsequently improved. The limit of applications of Gear Pumps has been reached when the transfer medium does not have the required lubricity for a proper function of the pump and a high working pressure is needed at the same time. Such problematic fluids are for example silicates (sodium silicate), isocyanates and polyols with hard fillers as can be found in the…
File type: application/pdf
Referenced at: