Mechanical expansion shafts E X P A N S I O N U N I T S Pneumatic expansion shafts Mechanical expansion shafts Expansion couplings Expansion chucks and adapters Friction and knife shafts Shaft handling 2 . 3 ❯ Page 2.1 Mechanically activated 2.1.1 Mech. expansion shaft Series 416 4 2.2 Pneumatically activated 2.2.1 Mech. expansion shaft Series 401 6 2.2.2 Mech. expansion shaft Series 745 8 2.2.3 Mech. expansion shaft Series 410 10 2.3 Customised versions 12 2.4 Inquiry data sheet 13 Mechanical expansion shafts Expansion couplings Expansion chucks and adapters Friction and knife shafts Shaft…
File type: application/pdf
Referenced at:
Mechanical expansion shafts E X P A N S I O N U N I T S Pneumatic expansion shafts Mechanical expansion shafts Expansion couplings Expansion chucks and adapters Friction and knife shafts Shaft handling 2 . 3 ❯ Page 2.1 Mechanically activated 2.1.1 Mech. expansion shaft Series 416 4 2.2 Pneumatically activated 2.2.1 Mech. expansion shaft Series 401 6 2.2.2 Mech. expansion shaft Series 745 8 2.2.3 Mech. expansion shaft Series 410 10 2.3 Customised versions 12 2.4 Inquiry data sheet 13 Mechanical expansion shafts Expansion couplings Expansion chucks and adapters Friction and knife shafts Shaft…
File type: application/pdf
Referenced at:
14 110/117 ED 1/8 — The PVE pumps are variable displacement vane pumps with direct pressure regulator. — The pump group is complete with hydrostatic axial compensation distribution plates that improve the volumetric efficiency and reduce wear of the components. — The pressure regulator adjustable load spring keeps the pump group cam ring in eccentric position. When the delivery pressure equals the pressure corresponding to the spring setting, the cam ring is moved so to reduce the displacement, adjusting the flow rate to the values required by the plant. In zero flow demand conditions, the…
File type: application/pdf
Referenced at:
14 110/117 ED 1/8 — The PVE pumps are variable displacement vane pumps with direct pressure regulator. — The pump group is complete with hydrostatic axial compensation distribution plates that improve the volumetric efficiency and reduce wear of the components. — The pressure regulator adjustable load spring keeps the pump group cam ring in eccentric position. When the delivery pressure equals the pressure corresponding to the spring setting, the cam ring is moved so to reduce the displacement, adjusting the flow rate to the values required by the plant. In zero flow demand conditions, the…
File type: application/pdf
Referenced at:
Gear pumps catalogue Book 1.1 www.caproni.bg caproni@caproni.bg Pump type: Group 10 Pump type Page 10A(C)...X001 4 10A(C)...X017 5 10A(C)...X026 6 10A(C)...X027 7 10A(C)...X053 8 10A(C)...X054 9 10A(C)...X055 10 10A(C)...X056 11 10A(C)...X057 12 10A(C)...X115 13 10A(C)...X125 14 10A(C)...X131 15 10A(C)...X135 16 10A(C)...X142 17 10A(C)...X174 18 10A(C)...X175 19 10A(C)...X176 20 10A(C)...X179 21 10A(C)...X181 22 10A(C)...X182 23 10A(C)...X230 24 10A(C)...X231 25 10A(C)...X238 26 10A(C)...X244 27 10A(C)...X254 28 10A(C)...X255 29 10A(C)...X257 30 10A(C)...X278 31 10A(C)...X302 32 10A(C)...X303…
File type: application/pdf
Referenced at:
Gear pumps catalogue Book 1.1 www.caproni.bg caproni@caproni.bg Pump type: Group 10 Pump type Page 10A(C)...X001 4 10A(C)...X017 5 10A(C)...X026 6 10A(C)...X027 7 10A(C)...X053 8 10A(C)...X054 9 10A(C)...X055 10 10A(C)...X056 11 10A(C)...X057 12 10A(C)...X115 13 10A(C)...X125 14 10A(C)...X131 15 10A(C)...X135 16 10A(C)...X142 17 10A(C)...X174 18 10A(C)...X175 19 10A(C)...X176 20 10A(C)...X179 21 10A(C)...X181 22 10A(C)...X182 23 10A(C)...X230 24 10A(C)...X231 25 10A(C)...X238 26 10A(C)...X244 27 10A(C)...X254 28 10A(C)...X255 29 10A(C)...X257 30 10A(C)...X278 31 10A(C)...X302 32 10A(C)...X303…
File type: application/pdf
Referenced at:
ROBOT CALIBRATION WITH TCP-MEASURING INSTRUMENTS FROM CAPTRON Application Notewww.captron.com ROBOT CALIBRATION WITH TOOL-CENTER-POINT MEASURING Q U A L I T Y M A D E I N B A V A R I A Nachher Figure 1: Tool coordinate system (TCP) relative to the robot’s flange coordinate system Zflange Ztool Ytool Xtool Xflange Yflange TCP State-of-the-art robotic automation systems rely on high accuracy. Whenever harsh environments, wear, or tool changes are part of the application, repeated tool checks or recalibrations are required to maintain high accuracy and quality over time. To describe a tool in…
File type: application/pdf
Referenced at:
ROBOT CALIBRATION WITH TCP-MEASURING INSTRUMENTS FROM CAPTRON Application Notewww.captron.com ROBOT CALIBRATION WITH TOOL-CENTER-POINT MEASURING Q U A L I T Y M A D E I N B A V A R I A Nachher Figure 1: Tool coordinate system (TCP) relative to the robot’s flange coordinate system Zflange Ztool Ytool Xtool Xflange Yflange TCP State-of-the-art robotic automation systems rely on high accuracy. Whenever harsh environments, wear, or tool changes are part of the application, repeated tool checks or recalibrations are required to maintain high accuracy and quality over time. To describe a tool in…
File type: application/pdf
Referenced at:
Genspec GS4200H ® Hydrogen Compatible Pressure Transmitter Vers. 28/9/Eng • Compatible for use within Hydrogen based environment • Silicon-on-Sapphire sensor technology for outstanding performance • Tested to ISO 11114-2:2017 according to EC79/2009 and EU406/2010 • Pressure ranges to 1,500 bar • Specialist High Strength titanium alloy sensor • Excellent Corrosion resistance • High resistance to overpressure and pressure transients • ATEX/IECEx option available (includes M1 for mining applications) • DNV-GL certification available Genspec GS4200H ® Technical Data Hydrogen Compatible Pressure…
File type: application/pdf
Referenced at:
Genspec GS4200H ® Hydrogen Compatible Pressure Transmitter Vers. 28/9/Eng • Compatible for use within Hydrogen based environment • Silicon-on-Sapphire sensor technology for outstanding performance • Tested to ISO 11114-2:2017 according to EC79/2009 and EU406/2010 • Pressure ranges to 1,500 bar • Specialist High Strength titanium alloy sensor • Excellent Corrosion resistance • High resistance to overpressure and pressure transients • ATEX/IECEx option available (includes M1 for mining applications) • DNV-GL certification available Genspec GS4200H ® Technical Data Hydrogen Compatible Pressure…
File type: application/pdf
Referenced at: