Special-Sensors for Automation ISO 9001 certified Infrared Detect ors ■ Measuring range 50...2000 °C ■ Analog and switching output ■ Fibre-optic up to 350 °C ■ For heavy industry - IP 68 EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.com6.02 EE60214 Function and application Where conventional sensors would fail due to too high temperature, infrared detectors working on a non-contact principle can be used. They respond to the radiated heat of the hot materials. Compact units with optics are used for distances of 2 to 8 m from the object. For distances of only a few cm,…
File type: application/pdf
Referenced at:
Special-Sensors for Automation ISO 9001 certified Infrared Detect ors Measuring-range 50...2000 °C Analog and switching output Fibre-optic up to 350 °C For heavy industry - IP 68 EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.com6.02 EE60410 Function and application Where conventional sensors would fail due to too high temperature, infrared detectors working on a non-contact principle can be used. They respond to the radiated heat of the hot materials. Compact units with optics are used for distances of 2 to 8 m from the object. For distances of only a few cm, heat-resistant…
File type: application/pdf
Referenced at:
96 www.danahermotion.com [Limberg Box Patch : TrimBox [0] BleedBox [3] MediaBox [10] Patch : Page 94] 97 Linear Units www.danahermotion.com Linear Units with Belt Drive and Wheel Guide SpeedLine, ForceLine Typical Applications Typical applications are where low to medium loads needs to be moved at high speed and acceleration. Typical examples are in packaging, cutting, pick and place and materials handling applications where the cycle times are critical. Velocity Acceleration Repeatability Force Stiffness Cost Maintenance Noise Guide Robustness Load Torque [Limberg Box Patch : TrimBox [0]…
File type: application/pdf
Referenced at:
Precision Machinery Company Swash-plate Axial Piston Pump K3VL Series CONTENTS Specifications and Features 1. Ordering Code 1-1. Pump Options 2. Technical Information 2-1. Technical Data 2-2. Specifications 2-3. Performance Data 2-4. Radial Loading Capacity 2-5. Functional Description of Regulator 2-6. Torque Limiter Settings 2-7. Installation 3. Dimensions 3-1. K3VL28 Installation 3-2. K3VL45/60 Installation 3-3. K3VL80 Installation 3-4. K3VL112/140 Installation 3-5. K3VL200 Installation 3-6. K3VL200H Installation 3-7. Electric Displacement Control 3-8. Unloading & Proportional Pressure…
File type: application/pdf
Referenced at:
Precision Machinery Company Swash-plate Axial Piston Pump K3VL Series CONTENTS Specifications and Features 1. Ordering Code 1-1. Pump Options 2. Technical Information 2-1. Technical Data 2-2. Specifications 2-3. Performance Data 2-4. Radial Loading Capacity 2-5. Functional Description of Regulator 2-6. Torque Limiter Settings 2-7. Installation 3. Dimensions 3-1. K3VL28 Installation 3-2. K3VL45/60 Installation 3-3. K3VL80 Installation 3-4. K3VL112/140 Installation 3-5. K3VL200 Installation 3-6. K3VL200H Installation 3-7. Electric Displacement Control 3-8. Unloading & Proportional Pressure…
File type: application/pdf
Referenced at:
GENSPEC© Dynamic GD4200HUSB Hydrogen Compatible Digital Pressure Transmitter Materials used in the manufacture of the Hydrogen range have been tested based on ISO 11114-2:2017 in accordance to the European Regulations EC 79/2009 and EU 406/2010 to determine an "embrittlement index" of the material when placed in a saturated environment over an extended period of time. Results have provided a Pass rating to the compatibility of the specialist Titanium Alloy of the range against Hydrogen. GENSPEC© GD4200HUSB Digital Pressure Tranmsitter for Hydrogen • Compatible for use within Hydrogen based…
File type: application/pdf
Referenced at:
GENSPEC© Dynamic GD4200HUSB Hydrogen Compatible Digital Pressure Transmitter Materials used in the manufacture of the Hydrogen range have been tested based on ISO 11114-2:2017 in accordance to the European Regulations EC 79/2009 and EU 406/2010 to determine an "embrittlement index" of the material when placed in a saturated environment over an extended period of time. Results have provided a Pass rating to the compatibility of the specialist Titanium Alloy of the range against Hydrogen. GENSPEC© GD4200HUSB Digital Pressure Tranmsitter for Hydrogen • Compatible for use within Hydrogen based…
File type: application/pdf
Referenced at:
www.suco.de 54 Electronic pressure switches Ceramic sensor with thick film technology for high accuracy Electronic evaluation of switching point permits extremely small or very large hysteresis settings Switching point easily set by the user (menu guided for type 0570) CE marking SUCO electronic switches are covered by the EMC Directive 89/336/EC. An EC Declaration of Conformity has been issued for these pressure switches and is on file at our offices. The corresponding switches bear the CE mark in our catalogue. RoHS compliant www.suco.de 55 0520 0570 Switching fuction: Normally open /…
File type: application/pdf
Referenced at:
652 Compressed air 1.0 1.5 5 to 60 0.02 to 0.5 (0.01 to 0.2) (Note 1) 0.001 (lock sensitivity 0.004) (Note 2) 1.5 (Note 3) Push-in joint: 4, 6 Rc1/8 90 Specifications Descriptions Working fluid Max. working pressure Withstanding pressure Ambient temperature range Set pressure range Sensitivity Air consumption Port size Product weight Note 1: Values in parentheses are for low pressure. Note 2: Set pressure sensitivity for the pressure adjustment knob block's minimum spacing. Note 3: Value for secondary side setting pressure 0.1 MPa. IN-OUT GAUGE Mpa Mpa Mpa Mpa /min g RJB500 Flow characteristic…
File type: application/pdf
Referenced at:
652 Compressed air 1.0 1.5 5 to 60 0.02 to 0.5 (0.01 to 0.2) (Note 1) 0.001 (lock sensitivity 0.004) (Note 2) 1.5 (Note 3) Push-in joint: 4, 6 Rc1/8 90 Specifications Descriptions Working fluid Max. working pressure Withstanding pressure Ambient temperature range Set pressure range Sensitivity Air consumption Port size Product weight Note 1: Values in parentheses are for low pressure. Note 2: Set pressure sensitivity for the pressure adjustment knob block's minimum spacing. Note 3: Value for secondary side setting pressure 0.1 MPa. IN-OUT GAUGE Mpa Mpa Mpa Mpa /min g RJB500 Flow characteristic…
File type: application/pdf
Referenced at: