1.34 3d d ra w in gs a va ila bl e at w w w .v uo to te cn ic a. ne t conversion ratio: inch = ; pounds = = 25.4 453.6 0.4536 mm g Kg FLat RectanGuLaR cups WItH suppoRt These cups are recommended for working surfaces for clamping wooden panels, marble, granite, ceramic, glass, etc. They are obviously used to handle these materials. Their vertical and low lip allows for a firm grip on the surface to be clamped or handled, eliminating any oscillation and considerably reduces the air volume contained within, thus ensuring a quicker gripping and release. Cups in special compounds indicated at page…
File type: application/pdf
Referenced at:
Zahnrad-Durchflussmesser für Lackiertechnik Gear Type Flow Meter for painting technology Débitmètres à engrenages pour peintures VCL 0,1 Inhaltsverzeichnis Inhalt Seite Inhaltsverzeichnis 2 Beschreibung 2 Betriebskenngrößen 3 Werkstoffe 4 Typenschlüssel 4 Elektrische Kenngrößen 5 Signalverhalten 6 Explosionsgeschützte Ausführung 7 Technische Daten K-130/3-E-10 7 Durchflusswiderstand 10 Abmessungen VCL 0,1 PB RS/125 11 List of Contents Contents Page List of contents 2 Description 2 Operating characteristics 3 Materials 4 Type key 4 Electrical data 5 Signal characterisitcs 6 Explosion-proof…
File type: application/pdf
Referenced at:
Zahnrad-Durchflussmesser für Lackiertechnik Gear Type Flow Meter for painting technology Débitmètres à engrenages pour peintures VCL 0,1 Inhaltsverzeichnis Inhalt Seite Inhaltsverzeichnis 2 Beschreibung 2 Betriebskenngrößen 3 Werkstoffe 4 Typenschlüssel 4 Elektrische Kenngrößen 5 Signalverhalten 6 Explosionsgeschützte Ausführung 7 Technische Daten K-130/3-E-10 7 Durchflusswiderstand 10 Abmessungen VCL 0,1 PB RS/125 11 List of Contents Contents Page List of contents 2 Description 2 Operating characteristics 3 Materials 4 Type key 4 Electrical data 5 Signal characterisitcs 6 Explosion-proof…
File type: application/pdf
Referenced at:
JUNTAS ROTATIVAS Água Vapor Ar Óleo hidráulico Termo-fluido Vácuo Liquido refrigerante Aplicações especificas dos clientes C a tá lo g o G e ra l RU 124 P 2 Por favor desdobre par ver lista de selecção DEUBLIN O nosso objectivo: “Fazer todos os esforços para produ- zir o melhor produto do seu género que se apresenta no mercado”. Este princípio funciona como incentivo e compromisso em igual medida. A adesão a esta politica foi a responsá- vel pelo nosso crescimento desde uma pequena ofi cina de garagem até ao maior fabricante mundial de Juntas Rotativas com uma vasta rede mundial de vendas e…
File type: application/pdf
Referenced at:
JUNTAS ROTATIVAS Água Vapor Ar Óleo hidráulico Termo-fluido Vácuo Liquido refrigerante Aplicações especificas dos clientes C a tá lo g o G e ra l RU 124 P 2 Por favor desdobre par ver lista de selecção DEUBLIN O nosso objectivo: “Fazer todos os esforços para produ- zir o melhor produto do seu género que se apresenta no mercado”. Este princípio funciona como incentivo e compromisso em igual medida. A adesão a esta politica foi a responsá- vel pelo nosso crescimento desde uma pequena ofi cina de garagem até ao maior fabricante mundial de Juntas Rotativas com uma vasta rede mundial de vendas e…
File type: application/pdf
Referenced at:
POWERmasterS C20 ● Vorschubschlitten pneumohydraulisch ▲ Slide unit pneumatic, hydraulic feed control ■ Unité d’avance oléopneumatique ● Technische Daten ▲ Technical Data ■ Caractéristiques techniques Gesamthub 150 oder 300 mm Total stroke 150 or 300 mm Course totale 150 ou 300 mm Arbeitshub PH-S, PH-E 75 mm Working stroke PH-S, PH-E 75 mm Course de travail PH-S, PH-E 75 mm Arbeitshub PH-C 150/300 mm Working stroke PH-C 150/300 mm Course de travail PH-C 150/300 mm Vorschubkraft bei 6 bar 1870 N Thrust force at 6 bar 1870 N Force de poussée à 6 bars 1870 N Rückhubkraft bei 6 bar 1020 N Return…
File type: application/pdf
Referenced at:
98 Read the precautions on pages 7 to 12 in the introduction before use. Metal free design with flow rate adjustment and closing functions MMD20·MMD30·MMD40 Series Chemical liquid manual valve Subject to Export Trade Control Ordinances *Target: Valves with Ø12 or larger orifice Specifications Internal structure and parts list Working fluid Fluid temperature Withstanding pressure Working pressure range Valve seat leakage Ambient temperature Installation attitude Connection (Note 1) Orifice Cv value Chemical liquids, pure water, N2 gas, air 5 to 60 (5 to 90) (Note 2) 1.4 0 (at, water pressure) 0…
File type: application/pdf
Referenced at:
98 Read the precautions on pages 7 to 12 in the introduction before use. Metal free design with flow rate adjustment and closing functions MMD20·MMD30·MMD40 Series Chemical liquid manual valve Subject to Export Trade Control Ordinances *Target: Valves with Ø12 or larger orifice Specifications Internal structure and parts list Working fluid Fluid temperature Withstanding pressure Working pressure range Valve seat leakage Ambient temperature Installation attitude Connection (Note 1) Orifice Cv value Chemical liquids, pure water, N2 gas, air 5 to 60 (5 to 90) (Note 2) 1.4 0 (at, water pressure) 0…
File type: application/pdf
Referenced at:
98 Read the precautions on pages 7 to 12 in the introduction before use. Metal free design with flow rate adjustment and closing functions MMD20·MMD30·MMD40 Series Chemical liquid manual valve Subject to Export Trade Control Ordinances *Target: Valves with Ø12 or larger orifice Specifications Internal structure and parts list Working fluid Fluid temperature Withstanding pressure Working pressure range Valve seat leakage Ambient temperature Installation attitude Connection (Note 1) Orifice Cv value Chemical liquids, pure water, N2 gas, air 5 to 60 (5 to 90) (Note 2) 1.4 0 (at, water pressure) 0…
File type: application/pdf
Referenced at:
14 101/318 ED 1/10 RV1D VARIABLE DISPLACEMENT VANE PUMPS WITH DIRECT PRESSURE ADJUSTER SERIES 10 OPERATING PRINCIPLE — The RV1D pumps are variable displacement vane pumps with mechanical pressure compensator. — The pressure compensator keeps the cam ring of the pumping group in the eccentric position with use of an adjustable load spring. When the delivery pressure equals the pressure corresponding to the spring setting, the cam ring is moved toward the center instantaneously, adjusting the flow rate to the values required by the plant. — Energy consumption is reduced and adequate in every…
File type: application/pdf
Referenced at: