442 Miniature regulator RB500 Series Compact / space saving structure Port size: Push-in joint 4 and 6 dia. JIS symbol CAD DATA AVAILABLE. Symbol Descriptions Blank P L N T Blank Note 1 G39 P11 Standard Option S L S L C4 C6 Port size D ire ct io n IN OUT Standard products Panel mount Note 2 For low pressure Non-relief Without pressure gauge 21dia. 0 to 1.0MPa gauge 27 dia. 0 to 0.4MPa gauge 27 dia. 0 to 1.0MPa gauge Ozone proof specifications (custom order) Straight Elbow Straight Elbow 4 dia. 6 dia. How to order AccessoryC OptionB ConnectionA Model ConnectionA AccessoryC OptionB SSC4 P…
File type: application/pdf
Referenced at:
442 Miniature regulator RB500 Series Compact / space saving structure Port size: Push-in joint 4 and 6 dia. JIS symbol CAD DATA AVAILABLE. Symbol Descriptions Blank P L N T Blank Note 1 G39 P11 Standard Option S L S L C4 C6 Port size D ire ct io n IN OUT Standard products Panel mount Note 2 For low pressure Non-relief Without pressure gauge 21dia. 0 to 1.0MPa gauge 27 dia. 0 to 0.4MPa gauge 27 dia. 0 to 1.0MPa gauge Ozone proof specifications (custom order) Straight Elbow Straight Elbow 4 dia. 6 dia. How to order AccessoryC OptionB ConnectionA Model ConnectionA AccessoryC OptionB SSC4 P…
File type: application/pdf
Referenced at:
442 Miniature regulator RB500 Series Compact / space saving structure Port size: Push-in joint 4 and 6 dia. JIS symbol CAD DATA AVAILABLE. Symbol Descriptions Blank P L N T Blank Note 1 G39 P11 Standard Option S L S L C4 C6 Port size D ire ct io n IN OUT Standard products Panel mount Note 2 For low pressure Non-relief Without pressure gauge 21dia. 0 to 1.0MPa gauge 27 dia. 0 to 0.4MPa gauge 27 dia. 0 to 1.0MPa gauge Ozone proof specifications (custom order) Straight Elbow Straight Elbow 4 dia. 6 dia. How to order AccessoryC OptionB ConnectionA Model ConnectionA AccessoryC OptionB SSC4 P…
File type: application/pdf
Referenced at:
safecap Zweihandsteuerung safecap two-hand safety control 2 3 I n h a l t ■ Einführung introduct ion safecap Sicherhei tstechnik safecap safety technology 4-5 ■ SCA4-185Z-S SCB4-185Z-S safecap A+B Einzelsensor safecap A+B single sensor 6-7 CAPTRON Electronic GmbH Johann-G. -Gutenberg-St r. 7 D - 82140 Olch ing Fon +49 (0 )8142 - 44 88 - 0 Fax +49 (0 )8142 - 44 88 - 100 in fo@capt ron .de www.capt ron .de c o n t e n t ■ Zubehör ■ accessory ■ safecap4 set1 safecap A+B mastercap Kabel A+B 2m safecap A+B mastercap cable A+B 2m ■ safecap4 set2 safecap A+B mastercap Kabel A+B 5m safecap A+B…
File type: application/pdf
Referenced at:
safecap Zweihandsteuerung safecap two-hand safety control 2 3 I n h a l t ■ Einführung introduct ion safecap Sicherhei tstechnik safecap safety technology 4-5 ■ SCA4-185Z-S SCB4-185Z-S safecap A+B Einzelsensor safecap A+B single sensor 6-7 CAPTRON Electronic GmbH Johann-G. -Gutenberg-St r. 7 D - 82140 Olch ing Fon +49 (0 )8142 - 44 88 - 0 Fax +49 (0 )8142 - 44 88 - 100 in fo@capt ron .de www.capt ron .de c o n t e n t ■ Zubehör ■ accessory ■ safecap4 set1 safecap A+B mastercap Kabel A+B 2m safecap A+B mastercap cable A+B 2m ■ safecap4 set2 safecap A+B mastercap Kabel A+B 5m safecap A+B…
File type: application/pdf
Referenced at:
HYDROGEN COMPATIBLE USB PRESSURE TRANSDUCER DYNAMIC GD4200HUSB Vers. 21/12/Eng • Compatible for use within Hydrogen based environments • Sample rate software selection up to 1,000 Hz • Silicon-on-Sapphire pressure sensor technology • Choice of pressure ranges from vacuum to 5,000 bar • Accuracy (NLHR) ±0.15% of span BFSL • Auto detect and configuration • USB 2.0 compatible • ESI-USB© downloadable software with auto update • Measure & record up to 16 pressure inputs together • Create customised test certificate • Automatic temperature compensation • Support for easy integration with…
File type: application/pdf
Referenced at:
HYDROGEN COMPATIBLE USB PRESSURE TRANSDUCER DYNAMIC GD4200HUSB Vers. 21/12/Eng • Compatible for use within Hydrogen based environments • Sample rate software selection up to 1,000 Hz • Silicon-on-Sapphire pressure sensor technology • Choice of pressure ranges from vacuum to 5,000 bar • Accuracy (NLHR) ±0.15% of span BFSL • Auto detect and configuration • USB 2.0 compatible • ESI-USB© downloadable software with auto update • Measure & record up to 16 pressure inputs together • Create customised test certificate • Automatic temperature compensation • Support for easy integration with…
File type: application/pdf
Referenced at:
HYDROGEN COMPATIBLE USB PRESSURE TRANSDUCER DYNAMIC GD4200HUSB Vers. 21/12/Eng • Compatible for use within Hydrogen based environments • Sample rate software selection up to 1,000 Hz • Silicon-on-Sapphire pressure sensor technology • Choice of pressure ranges from vacuum to 5,000 bar • Accuracy (NLHR) ±0.15% of span BFSL • Auto detect and configuration • USB 2.0 compatible • ESI-USB© downloadable software with auto update • Measure & record up to 16 pressure inputs together • Create customised test certificate • Automatic temperature compensation • Support for easy integration with…
File type: application/pdf
Referenced at:
HYDROGEN COMPATIBLE USB PRESSURE TRANSDUCER DYNAMIC GD4200HUSB Vers. 21/12/Eng • Compatible for use within Hydrogen based environments • Sample rate software selection up to 1,000 Hz • Silicon-on-Sapphire pressure sensor technology • Choice of pressure ranges from vacuum to 5,000 bar • Accuracy (NLHR) ±0.15% of span BFSL • Auto detect and configuration • USB 2.0 compatible • ESI-USB© downloadable software with auto update • Measure & record up to 16 pressure inputs together • Create customised test certificate • Automatic temperature compensation • Support for easy integration with…
File type: application/pdf
Referenced at:
HYDROGEN COMPATIBLE USB PRESSURE TRANSDUCER DYNAMIC GD4200HUSB Vers. 21/12/Eng • Compatible for use within Hydrogen based environments • Sample rate software selection up to 1,000 Hz • Silicon-on-Sapphire pressure sensor technology • Choice of pressure ranges from vacuum to 5,000 bar • Accuracy (NLHR) ±0.15% of span BFSL • Auto detect and configuration • USB 2.0 compatible • ESI-USB© downloadable software with auto update • Measure & record up to 16 pressure inputs together • Create customised test certificate • Automatic temperature compensation • Support for easy integration with…
File type: application/pdf
Referenced at: