Special-Sensors for Automation Inductive Sensors EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.com3.02 E30410 Inductive Sensors Contents Terminology for inductive measurment ......................................................... 3.03 - 3.05 Application notes ...................................................................................................................3.06 Extreme environment Metal face sensors Series IGV / IGVU...-C / IGVW ............................................................. 3.07 - 3.10 POLAR-Series climatic-proofed – 60 °C Series IGMP…
File type: application/pdf
Referenced at:
MHF POLYdrill F 10 ∅ 1,5–25 M 1,2–22 min. 7 max. 190 min-1 2500–8000 S MHF 0-70 1,5 1,2 4 7,0 50 59 977 01 59 977 25 59 977 49 — — — — — — MHF 1-100 2,5 2,0 4 9,0 70 59 977 02 59 977 26 59 977 50 — — — — — — MHF 3-100 5,0 4,0 4 13,5 70 59 977 03 59 977 27 59 977 51 — — — — — — MHF 5-130 10,0 8,0 5 21,0 80 59 977 04 59 977 28 59 977 52 59 978 01 — — — — — MHF 0-100 1,5 1,2 6 7,0 70 59 977 05 59 977 29 59 977 53 59 978 02 59 978 22 — — — — MHF 1-130 2,5 2,0 6 9,0 90 59 977 06 59 977 30 59 977 54 59 978 03 59 978 23 — — — — MHF 3-130 5,0 4,0 6 13,5 100 59 977 07 59 977 31 59 977 55 59 978 04 59…
File type: application/pdf
Referenced at:
25.4 453.6 0.4536 mm g Kg Conversion ratio: inch = ; pounds = = GAS-NPT thread adapters available at page 1.117 7 7.13 Curve regarding capacity (referring to a 1013 bar pressure) Curve regarding the emptying of a 100-litre volume Curve regarding capacity (referring to the suction pressure) To calculate the emptying time of a volume V1, apply the formula V1 : Volume to be emptied t1 : Time to be calculated (sec) t : Time obtained in the table (sec) Time Time Time Time Vacuum mbar Vacuum mbarVacuum mbar Vacuum mbar Capacity cum/h Capacity cum/h Capacity cum/h Capacity cum/h Curve regarding…
File type: application/pdf
Referenced at:
page 49 2.4 Pilot Actuated Valves Selected models are available for explosion hazardous environment. They are ATEX-Ex certified. For detailed information refer to chapter 2.14. 2.4 Selected valves can be used for technical vacuum too. 316Selected models are available in stainless steel. For detailed information refer to chapter 2.12. Selected models are available for low temperature application. For detailed information refer to chapter 2.11. + – 0 Selected models can be equipped with FKM seals for high temperature environment up to 120 °C. page 50 2.4.1.1 P 310 302/P 310 502 P 310 302 P 310…
File type: application/pdf
Referenced at:
page 49 2.4 Pilot Actuated Valves Selected models are available for explosion hazardous environment. They are ATEX-Ex certified. For detailed information refer to chapter 2.14. 2.4 Selected valves can be used for technical vacuum too. 316Selected models are available in stainless steel. For detailed information refer to chapter 2.12. Selected models are available for low temperature application. For detailed information refer to chapter 2.11. + – 0 Selected models can be equipped with FKM seals for high temperature environment up to 120 °C. page 50 2.4.1.1 P 310 302/P 310 502 P 310 302 P 310…
File type: application/pdf
Referenced at:
Linear Module, Tilting Module, Double Tilting Head LM, SM, DSK Product Catalog 06-2008 45 The PTM-Linear Modules – LM – work with our PTM-Actuators. In contrast to the normal linear units, the PTM-Linear Modules use a crank. Therefore there are many advantages. This causes a sinucidal move of the slide with high positioning accuracy and smooth end positioning. The reduced end speed is supported by the end position damping of the PTM-Actuators – DA –. The movements of the slide will be shock-free. The slide strokes are continuous adjustable between 0 and 25, 30, 52 or 90 mm. The PTM-Tilting…
File type: application/pdf
Referenced at:
25.4 453.6 0.4536 mm g Kg Conversion ratio: inch = ; pounds = = GAS-NPT thread adapters available at page 1.117 7 7.11 Curve regarding capacity (referring to a 1013 bar pressure) Curve regarding the emptying of a 100-litre volume Time Capacity To calculate the emptying time of a volume V1, apply the formula V1 : Volume to be emptied t1 : Time to be calculated (sec) t : Time obtained in the table (sec) Time Time Time Curve regarding capacity (referring to the suction pressure) Vacuum mbarVacuum mbar Vacuum mbar Vacuum mbar Capacity cum/h Capacity cum/h Capacity cum/h Capacity cum/h Time Vacuum…
File type: application/pdf
Referenced at:
page 135 2.8 Namur Valves Selected models are available for explosion hazardous environment. They are ATEX-Ex certified. Selected models are available for low temperature application. Temperature-range: - 50° C to + 50° C. For detailed information refer to chapter 2.9. Namur 1/4” also called “Namur 1” in accordance to VDI / VDE 3845. Namur 1/2” also called “Namur 2”. 2.8 page 3 Table of Contents page 10 Quick Finder for Manifold Systems 11 2.1 Mechanically Actuated Valves 2.1.1 3/2 way valves 12 2.1.1.1 BV/BR/BL 311 201 13 2.1.1.2 BV/BR/BL 311 202 14 2.1.1.3 BV/BR/BL 311 243 15 2.1.1.4…
File type: application/pdf
Referenced at:
14 110/117 ED 1/8 — The PVE pumps are variable displacement vane pumps with direct pressure regulator. — The pump group is complete with hydrostatic axial compensation distribution plates that improve the volumetric efficiency and reduce wear of the components. — The pressure regulator adjustable load spring keeps the pump group cam ring in eccentric position. When the delivery pressure equals the pressure corresponding to the spring setting, the cam ring is moved so to reduce the displacement, adjusting the flow rate to the values required by the plant. In zero flow demand conditions, the…
File type: application/pdf
Referenced at:
14 110/117 ED 1/8 — The PVE pumps are variable displacement vane pumps with direct pressure regulator. — The pump group is complete with hydrostatic axial compensation distribution plates that improve the volumetric efficiency and reduce wear of the components. — The pressure regulator adjustable load spring keeps the pump group cam ring in eccentric position. When the delivery pressure equals the pressure corresponding to the spring setting, the cam ring is moved so to reduce the displacement, adjusting the flow rate to the values required by the plant. In zero flow demand conditions, the…
File type: application/pdf