Änderungen vorbehalten / All rights for alterations reserved / Sous réserve de modifications Montage- und Bedienungsanleitung / Mounting and operating instructions / Instructions de service et de montage SensoPart Industriesensorik GmbH, D-79695 Wieden, Tel. +49 (0) 7665 - 94769 - 0 Fax +49 (0) 7665 - 94769 - 765, www.sensopart.com Printed in Germany Sensor Daten 1) Betriebstastweite: Blindzone: Grenztastweite: Öffnungswinkel des Schallfeldes: s. Schallfeld Auflösung: 0,20mm Ansprechverzögerung: 30 ms Synchronisation / Triggerung: extern Wiederholgenauigkeit: +0,15% vom Endwert der…
File type: application/pdf
Referenced at:
Vertretungen international und national, siehe hintere Ausklappseite / See the fold-out page at the back for international and national agents / Pour les agences internationales et nationales, voir la dernière page rabattable 04 Näherungsschal ter Magnet ic switches Interrupteurs magnét iques à contact Reed Flachschal ter Sur face mount swi tches Interrupteurs p la ts 143…147 Eisennäherungsschal ter Stee l sens ing prox imi ty swi tches Interrupteurs act ionnés par métaux magn. 148 Rohrschal ter Cy l indr ica l prox imi ty swi tches Interrupteurs cy l indr iques 149…153 Schl i tzschal ter Vane…
File type: application/pdf
Referenced at:
10 Read the precautions on pages 7 to 12 in the introduction before use. Air-operated valve for chemical liquids Orifice: Ø6.3 to Ø10 AMD31232 Series Specifications Working fluid Fluid temperature Withstanding pressure Working pressure range (A —> B) Working pressure range (B —> A) Valve seat leakage Back pressure Ambient temperature Frequency Installation attitude Orifice Cv value Bypass orifice (when bypass is installed) Operation section Chemical liquids, pure water (Note 1) 5 to 90 (5 to 160) (Note 5) 0.9 0 to 0.3 (Note 3) 0 to 0.1 (Note 3) 0 (at, water pressure) 0 to 0.1 (Note 3) 0 to 60…
File type: application/pdf
Referenced at:
10 Read the precautions on pages 7 to 12 in the introduction before use. Air-operated valve for chemical liquids Orifice: Ø6.3 to Ø10 AMD31232 Series Specifications Working fluid Fluid temperature Withstanding pressure Working pressure range (A —> B) Working pressure range (B —> A) Valve seat leakage Back pressure Ambient temperature Frequency Installation attitude Orifice Cv value Bypass orifice (when bypass is installed) Operation section Chemical liquids, pure water (Note 1) 5 to 90 (5 to 160) (Note 5) 0.9 0 to 0.3 (Note 3) 0 to 0.1 (Note 3) 0 (at, water pressure) 0 to 0.1 (Note 3) 0 to 60…
File type: application/pdf
Referenced at:
10 Read the precautions on pages 7 to 12 in the introduction before use. Air-operated valve for chemical liquids Orifice: Ø6.3 to Ø10 AMD31232 Series Specifications Working fluid Fluid temperature Withstanding pressure Working pressure range (A —> B) Working pressure range (B —> A) Valve seat leakage Back pressure Ambient temperature Frequency Installation attitude Orifice Cv value Bypass orifice (when bypass is installed) Operation section Chemical liquids, pure water (Note 1) 5 to 90 (5 to 160) (Note 5) 0.9 0 to 0.3 (Note 3) 0 to 0.1 (Note 3) 0 (at, water pressure) 0 to 0.1 (Note 3) 0 to 60…
File type: application/pdf
Referenced at:
6 Read the precautions on pages 7 to 12 in the introduction before use. AMD01232 Series Air-operated valve for chemical liquids Special PPS enables standard types to be used with hydrofluoric acids. Orifice: Ø3 to Ø4 Working fluid Fluid temperature Withstanding pressure Working pressure range (A —> B) Working pressure range (B —> A) Valve seat leakage Back pressure Ambient temperature Frequency Installation attitude Connection Orifice Cv value Operation section ˚C MPa MPa MPa cm3/min MPa ˚C Operation pressure range MPa Operation pressure connection port Specifications Pure water, chemical…
File type: application/pdf
Referenced at:
6 Read the precautions on pages 7 to 12 in the introduction before use. AMD01232 Series Air-operated valve for chemical liquids Special PPS enables standard types to be used with hydrofluoric acids. Orifice: Ø3 to Ø4 Working fluid Fluid temperature Withstanding pressure Working pressure range (A —> B) Working pressure range (B —> A) Valve seat leakage Back pressure Ambient temperature Frequency Installation attitude Connection Orifice Cv value Operation section ˚C MPa MPa MPa cm3/min MPa ˚C Operation pressure range MPa Operation pressure connection port Specifications Pure water, chemical…
File type: application/pdf
Referenced at:
6 Read the precautions on pages 7 to 12 in the introduction before use. AMD01232 Series Air-operated valve for chemical liquids Special PPS enables standard types to be used with hydrofluoric acids. Orifice: Ø3 to Ø4 Working fluid Fluid temperature Withstanding pressure Working pressure range (A —> B) Working pressure range (B —> A) Valve seat leakage Back pressure Ambient temperature Frequency Installation attitude Connection Orifice Cv value Operation section ˚C MPa MPa MPa cm3/min MPa ˚C Operation pressure range MPa Operation pressure connection port Specifications Pure water, chemical…
File type: application/pdf
Referenced at:
Balancing Unit BBS Series CC-960A Lightly supporting heavy objects just with air Balancing Unit BBS Series Move objects weighing up to 200 kg effortlessly! Balancing Unit BBS-A BBS-O Force of 5 kg or less move objects weighing up to 200 kg! Ensure personnel safety at sites where heavy objects are handled. No more inching along! Objects glide as if guided by hand. Flexibly handle changes in weight (without adjustment) Even if weight changes with the transported workpiece, these changes are automatically recognized so a suitable balance is maintained. (BBS-A type) Balance immediately after air…
File type: application/pdf
Referenced at:
High Pressure Gear Motors KM 2 2 KRACHT GmbH · Gewerbestr. 20 · 58791 Werdohl, Germany · Phone +49 23 92.935-0 · Fax +49 23 92.935 209 · Email info@kracht.eu · Web www.kracht.eu The construction (design principle) and materials of the KRACHT KM 2 series external gear motors make them perfect for use under the most extreme operating conditions. The main components form the housing and flange cover (see sectional drawing). They can be dynamically highly loaded, making them insensitive to pressure peaks and continuous vibrations. Large-surface-dimensioned, PTFE-Pb coated, bronze plain bearings on…